PDG-DXL2000 Expand Serial Command Functional Specifications
69/72
9.12 Other Status Read Command
9.12.1 CR_STATUS Command
Command “CR_STATUS”(CR)
Details
Get status of Projector behavior.
This command affects the same as ”CR0” of Basic Serial command, but this has
an error code.
Acceptable
“000_%1”[CR]
%1
“00”= Power ON
“80”= Stand by
“40”= Count down
“20”= Cooling down
“10”= Power failure
“28”= Cooling down due to abnormal temperature
“88”= Stand by after Cooling down
“24”= Power saving cooling down
“04”= Power saving
“21”= Cooling down due to Lamp failure
“81”= Stand by after Cooling down due to Lamp failure
Response
Unacceptable “Error Code”[CR]
9.12.2 CR_SIGNAL Command
Command “CR_SIGNAL”(CR)
Details
Get Signal status if there is signal or not
Acceptable
“000_%a”[CR]
%a
“ON” ------------------------ Signal is found
“OFF” ----------------------- There is no signal
Response
Unacceptable “Error code”[CR]
9.12.3 CR_VMUTE Command
Command “CR_VMUTE”[CR]
Details
Get setting status of No Show
Acceptable
“000_%a”[CR]
%a
“ON” -------- No Show is ON
“OFF” ------- No Show is OFF
Response
Unacceptable “Error code”[CR]
9.12.4 CR_FREEZE Command
Command “CR_FREEZE”[CR]
Details
Get setting status of Freeze
Acceptable
“000_%a”[CR]
%a
“ON” ---------------------- Freeze is ON
“OFF” --------------------- Freeze is OFF
Response
Unacceptable “Error code”[CR]