Remote Setup
68
To set the alarm input/output conditions of the alarm input/output terminals.
b
Alarm Out
Sets whether to output or not alarm signal from this unit.
• ON:
Output enabled
• OFF:
Output disabled
b
Setting an alarm output terminal
Specify an alarm output terminal number (1 - 4) and set the
alarm output conditions.
1
Alarm Out No.
Specifies the alarm output terminal number (1 - 4).
2
Alarm In
Outputs an alarm signal when the specified external alarm
input terminal receives an input.
Input terminal number
DSR-2116: 1 -16, DSR-2108: 1 - 8
3
Motion ON
Outputs an alarm signal when the specified video input
terminal receives a motion detection signal.
Input terminal number
DSR-2116: 1 -16, DSR-2108: 1 - 8
4
Video Loss On
Outputs an alarm signal when a video loss occurs in the
specified video input terminal.
Input terminal number
DSR-2116: 1 -16, DSR-2108: 1 - 8
5
HDD Error
Sets whether to output or not an alarm signal when a hard
disk error occurs.
• ON:
Alarm signal output enabled
• OFF:
Alarm signal output disabled
6
Alarm Duration
Sets the duration of the alarm output signal.
(3 - 255 SECONDS)
b
Setting an alarm input terminal
Specify an alarm input terminal number and set the type.
1
Alarm In No.
Specifies the alarm input terminal number.
Input terminal number
DSR-2116: 1 -16, DSR-2108: 1 - 8
2
Type
Sets the signal polarity of the specified alarm input
terminal.
• ----:
Alarm input detection disabled
• N/O (Normal Open):
Normally open, detects input when closed
• N/C (Normal Close):
Normally closed, detects input when opened