57
C. Check remote control unit.
D. Check fuse on the indoor PCB Ass'y.
E. Check TIMER on the remote control unit.
• Timer is turned ON. Check to see
if is displayed on remote
control.
YES
Cancel the timer mode.
ON
OK
OK
• Check fuse on indoor PCB Ass'y
for continuity. (F)
• Check operation lamp to see
if light is ON.
Light is OFF
• Measure resistance of primary and
secondary winding of transformer.
(TR)
Indoor PCB Ass'y or switch Ass'y is
defective.
OK
OK
• Measure resistance of indoor and/or
fan motor winding.
(FM)
• Measure resistance of compressor
motor winding. (CM)
OK
• Measure coil resistance of power
relay.
(PR)
Replace the fuse.
If fuse has been blown,
OK
• Try to run with another remote
control unit.
First remote control unit is defective.
• Check for residue buildup on
transmitter of remote control unit.
• Check for residue buildup on remote
control receiver on front of indoor
unit.
Clean transmitter.
Clean receiver.
000-111
SM
(18-68)
00.3.17
11:49
AM
y [ W 57
Summary of Contents for CH0951
Page 41: ...37 5 Printed circuit board POW KHS095A for KHS0951 Top view Bottom view ...
Page 42: ...38 6 Printed circuit board POW KHS125A for KHS1251 Top view Bottom view ...
Page 43: ...39 7 Printed circuit board POW KHS095B for KHS0951 and KHS1251 Top view Bottom view ...
Page 44: ...40 8 Printed circuit board POW KHS1852 for KHS1852 Top view Bottom view ...
Page 45: ...41 9 Printed circuit board POW CH095 for CH0951 CH1251 and CH1852 Top view ...
Page 72: ...68 INSTRUCTION MANUAL KHS0951 CH0951 KHS1251 CH1251 KHS1852 CH1852 APPENDIX ...