Troubleshooting
If your air conditioner does not work properly, first check the following points before requesting service. If it
still does not work properly, contact your dealer or service center.
Trouble
Possible Cause
Remedy
Air conditioner does not run
at all.
1. Power failure.
1. Restore power.
2. Leakage circuit breaker tripped.
2. Contact service center.
3. Line voltage is too low.
3. Consult your electrician or dealer.
4. Operation button is OFF.
4. Press the button again.
5. Batteries in remote control unit have run
down.
5. Replace batteries.
OPERATION lamp flashes
and air conditioner does not
operate.
Trouble in wiring system.
Contact service center.
Compressor runs but soon
stops.
Obstruction in front of condenser coil.
Remove obstruction.
Poor cooling (or heating)
performance.
1. Dirty or clogged air filter.
1. Clean air filter to improve airflow.
2. Heat source or many people in room.
2. Eliminate heat source if possible.
3. Doors and/or windows are open.
3. Shut them to keep the heat (or cold) out.
4. Obstacle near air intake or air discharge
port.
4. Remove it to ensure good airflow.
5. Thermostat is set too high for cooling (or
too low for heating).
5. Set the temperature lower (or higher).
6. (Outdoor temperature is too low.)
6. (Consult your dealer or try to use a
back-up heater.)
Clicking sound is heard from
the air conditioner.
In heating or cooling operation, any plastic
parts may expand or shrink due to a
sudden temperature change. In this event,
a clicking sound may occur.
This is normal, and the sound will soon
disappear.
OPERATION lamp lights but
outdoor unit will not run.
1. The use of portable telephones near the
air conditioner may cause disturbance to
its normal operation.
1. Turn off the power then restart the air
conditioner after 1 minute.
2. Consult your dealer.
Operating Range
The air conditioner is operable within the temperature ranges as listed below:
Temperature
Indoor Air Intake Temp.
Outdoor Air Intake Temp.
COOLING
Maximum
95
°
F DB/71
°
F WB
115
°
F DB
Minimum
67
°
F DB/57
°
F WB
67
°
F DB
HEATING
Maximum
80
°
F DB/67
°
F WB
75
°
F DB/65
°
F WB
Minimum
– DB/– WB
17
°
F DB/15
°
F WB
oi330000
26
OI-202-22EG
oi202000
Summary of Contents for CH0951
Page 41: ...37 5 Printed circuit board POW KHS095A for KHS0951 Top view Bottom view ...
Page 42: ...38 6 Printed circuit board POW KHS125A for KHS1251 Top view Bottom view ...
Page 43: ...39 7 Printed circuit board POW KHS095B for KHS0951 and KHS1251 Top view Bottom view ...
Page 44: ...40 8 Printed circuit board POW KHS1852 for KHS1852 Top view Bottom view ...
Page 45: ...41 9 Printed circuit board POW CH095 for CH0951 CH1251 and CH1852 Top view ...
Page 72: ...68 INSTRUCTION MANUAL KHS0951 CH0951 KHS1251 CH1251 KHS1852 CH1852 APPENDIX ...