31
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
115V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.40
0.70
9.4
10.5
Power Input
kW
0.034
0.081
1.085
1.20
Full Load Conditions Running Amps.
A
0.40
0.70
11.8
12.9
Power Input
kW
0.034
0.081
1.365
1.48
Rating Conditions
: Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor Air Temperature 115°F (46.1°C) D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
115V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.40
0.70
9.2
10.3
Power Input
kW
0.034
0.081
1.055
1.17
Full Load Conditions Running Amps.
A
0.40
0.70
10.9
12.0
Power Input
kW
0.034
0.081
1.255
1.37
Rating Conditions
: Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.
Indoor Unit
KHS1251
Outdoor Unit
CH1251
000-111
SM
(18-68)
00.3.17
11:49
AM
y [ W 31
Summary of Contents for CH0951
Page 41: ...37 5 Printed circuit board POW KHS095A for KHS0951 Top view Bottom view ...
Page 42: ...38 6 Printed circuit board POW KHS125A for KHS1251 Top view Bottom view ...
Page 43: ...39 7 Printed circuit board POW KHS095B for KHS0951 and KHS1251 Top view Bottom view ...
Page 44: ...40 8 Printed circuit board POW KHS1852 for KHS1852 Top view Bottom view ...
Page 45: ...41 9 Printed circuit board POW CH095 for CH0951 CH1251 and CH1852 Top view ...
Page 72: ...68 INSTRUCTION MANUAL KHS0951 CH0951 KHS1251 CH1251 KHS1852 CH1852 APPENDIX ...