4. Optical Filter Removal
Cabinet Front includes Optical Filter to protect the damage of Panel, improve picture quality, or prevent exposure of
interference. For removal of Optical Filter, remove screws of Fig.7-1 and Fig.7-2.
[NOTE]
The Optical Filter is easy to be damaged. Do not touch directly by hand. If there is the dust, remove it by watery
neutral detergent.
5. Servicing of Unit
Remove screws which fixed PWB for servicing unit.
For Sub Power Unit, remove the shield plate at first.
For Jack Unit, remove terminal plate together.
Note:
If the cable is fixed by ferrite core or CV band (fixer), remove it as the need arises. After servicing, it is neces-
sary to be fixed again to previous position.
6. Servicing of Panel Power Unit
Panel Power Unit is not included in Panel Module. Can be ordered. (Refer to parts list.)
The inside parts of Panel Power Unit are not supplied for servicing.
Fig. 7-2
■
PDP Panel Replacement
For change of PDP Panel (Module), proceed
1