Monitor
SY75C Excavator OMM
3-28
Operation and Maintenance Manual — 0220
SANY
Failure Codes Screen
The Failure Codes screen displays the seven failure codes
that could display:
•
E201 Voltage low
•
E202 Voltage high
•
P101 Engine oil pressure low
•
P104 Engine racing
•
P301 Coolant temperature high (clean radiator)
•
P401 Fuel level low
•
P501 Air cleaner plugged (replace air filter)
Press F4 to display the main operator screen.
Maintenance Information Screens
The machine maintenance system has a pop up notice that will display during start-up when scheduled
maintenance is required. The pop up block will disappear after one minute. The popup will not display during
operation.
There are six Maintenance Information screens, one each
for the six maintenance intervals (Daily, 50 Hours, 250
Hours, 500 Hours, 1000 Hours and 2000 Hours of service)
that list the scheduled maintenance procedures on the
maintenance information screens.
Current Failure Code:
Failure Codes:
Get failure information according to code:
E201 Voltage low
E202 Voltage high
P101 Engine oil pressure low
P104 Engine racing
P301 Coolant temperature high (clean radiator)
P401 Fuel level low
P501 Air cleaner plugged
Fig. 3-37
MAINTENANCE INFORMATION
50 H MAINTENANCE SCHEDULE
1. ENG OIL AND OIL FILTER - REPLACE
2. FAN BELT TENSION - CHECK AND ADJUST
3. BOLT AND NUT TIGHTENING TORQUE -
Fig. 3-38