9. Remove hydraulic suction strainer cover (d).
10. Add hydraulic oil through the suction strainer opening
until the hydraulic oil level shows full according to
decal (e) and sight gauge (f) on the hydraulic tank.
11. Replace the suction strainer O-ring.
12. Reinstall suction strainer filter cover (d).
13. Start the engine.
CAUTION!
Hydraulic oil may be hot and under pressure.
Always use caution when opening the hydraulic
system.
Fig. 5-77
d
e
f
Fig. 5-78
Fig. 5-79