Maintenance Procedures
SY75C Excavator OMM
5-36
Operation and Maintenance Manual — 0220
SANY
Engine Exhaust Pipe Clamps - Check
1. Open right rear door (a).
2. Check clamps (b) on the exhaust system for tightness.
3. Tighten as required.
4. Replace damaged or missing clamps.
5. Close the right side door when complete.
Collect Engine Oil Sample
1. Obtain an Oil Analysis Sample Kit from a SANY dealer.
2. Operate the machine until the engine oil is up to normal operating temperature.
3. Prepare the machine for service.
4. Clean the area around the engine oil dipstick and remove the dipstick.
5. Insert the oil sample tube into the dipstick tube and collect a sample of engine oil. Replace the dipstick.
6. Send the sample for testing in accordance
CAUTION!
Ensure that the engine is shut down and that the
exhaust has cooled down to a point where it can
be touched without burning. Failure to do so
could result in minor or moderate injury.
NOTICE!
It is critical that all material used to collect the sample is absolutely clean. Failure to adhere to
this warning can cause equipment damage and contaminate the sample.
Fig. 5-37
a
Fig. 5-38
b
Summary of Contents for SY75
Page 2: ......