Machine Controls
SY215C LC/SY225C LC Excavator OMM
3-32
Operation and Maintenance Manual — 1219
SANY
Maintenance Info Screen
Fig. 3-42
F5
F4
F3
F2
F1
0004551
NOTE:
Use this screen to view which procedures are
required for the machine when the periodic
maintenance umbrella icon illuminates on the
home screen.
1. Press F1 once at the Main Menu screen to navigate to
the Maintenance Info icon.
NOTE:
No password is required for this screen.
2. Press F3 to access the maintenance information screen.
•
No maintenance screen will appear if the umbrella
icon is off and no periodic maintenance is required.
•
The screen on the right is typical, in this case a
50-hour maintenance schedule.
•
Consecutive screens will display if extensive
periodic maintenance is required.
3. Do the following:
•
Press F3 on this screen, enter the password after
completion of the maintenance procedures, then
turn the key switch to OFF, and then back to ON to
confirm the selection and clear the umbrella icon
from the home screen.
•
Press F5 to return to the Main Menu screen without
making any changes.