[9] SPECIFICATIONS
9-1 General Specification
AC Rectifier form
: Half-wave rectifier form
Meter type
: Internal magnet, Taut band meter (15 µA)
Accuracy assurance Temperature/Humidity range
: 23
±
2
℃
75 %RH max. No condensation
Operating temperature and humidity
: 5
〜
31
℃,
80 %RH max.
31
<
〜
40
℃,
80
〜
50 %RH (decreasing linearly)
Storage temperature/Humidity range
:
−
10
〜
50
℃
70 %RH max. No condensation
Built-in battery : R6 (IEC) or UM-3 1.5 V
X
2, 6F22 9 V
X
1
*
Factory-preinstalled built-in battery
A battery for monitoring is preinstalled before shipping, therefore it may
run down sooner than the battery life specified in the instruction manual.
The ”battery for monitoring” is a battery to inspect the functions and
specifications of the product.
Built-in fuse
: F500 mAH/250 V
φ
5 X 20 mm Ceramic tube
Fast acting fuse. Blowout capacity : 1500 A
Dimension and Mass
: 165(H) X 106(W) X 46(D) mm
・
approx. 370 g
Accessories : Instruction manual 1 Spare fuse 1
Test leads TL-21a 1 Crip lead CL-506a 1
Environmental conditions: Indoor use Altitude up to 2000 m
Working circuit voltage: 600 VAC max.
— 47 —