background image

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

When using in a high or inclined position: 

 

 

 

 

 

 

 

 

 

FOR YOUR SAFE USAGE 

CAUTION : 

Improper handling of the conveyor may result in physical injury or damage! 

Transport and assembly 

  When transporting and assembling the conveyor, pay special attention not to drop it in order to 

avoid physical injury or damage. When lifting by crane, pay attention to the balance of the conveyor. 

Earth and leakage breaker 

  Ensure the conveyor is connected to earth at all times to prevent electric shock. Also ensure that 

an earth leakage breaker is connected to the power supply. 

A.

 

Prior To Use 

Emergency stop 

  Install an emergency stop device to immediately stop the conveyor in emergency. 

Start alarm 

  If it is not possible to supervise the operation of the full length of the conveyor from the operating 

position, install a start alarm for increased safety. 

Keep the conveyor dry at all times 

  Do NOT use the conveyor in wet or humid areas. Do NOT splash liquids onto the conveyor. Do 

NOT use or leave the conveyor outdoors. The machine is not waterproof. Do NOT touch electrical 
parts with wet hands. 

Do NOT use in an explosive atmosphere 

  (Avoid explosive gas, explosive dust, etc.) 

Lower cover and guard 

  Install the optional lower cover or guard in order to prevent entry under the conveyor. 

 

Guide rail, top and side covers 

  To prevent objects from falling off the conveyor, install the optional guide rail, top and/or side 

covers. 

 

Braking system 

  When using the conveyor on an incline, it is recommended that an optional braking system be 

installed, in order to prevent reverse or other incorrect running of the conveyor. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Environmental conditions 

Ambient temperature 
Ambient humidity 
Atmosphere 
Elevation 

NOTE

 

Using the conveyor in a strong electric field (eg near broadcasting devices or high- frequency welding 
machinery/equipment) could cause the conveyor to malfunction. In this case, install the conveyor at a 
sufficient distance. Alternatively shield completely to avoid any interference with the conveyor.   

Using an inverter to this machine could cause other machines to get effects of high-frequency. In this 
case, install the conveyor at a sufficient distance or shield completely. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION WHEN HANDLING 

 

:0℃ to +40℃

 

RH 85% max(Avoid condensation) 

Indoor(Avoid corrosive gases, dust, etc.) 

1,000m or less 

     

Summary of Contents for S-CON MINI SLIM

Page 1: ...1 S CON MINI SLIM OPERATING AND SERVICE MANUAL...

Page 2: ...manual where the machine is installed so that it may be referred to when needed TABLE OF CONTENTS 1 Caution When Handling 2 Component Names 3 Assembly 4 Running the Conveyor 5 Taking up the Belt 6 Be...

Page 3: ...ode Constant speed C Brushless motor variable speed B Motor output Code 30W 30 Code BG BW XG XW XB XX NO Specification Standard Other None Color Green White Green White Blue Other 20 JOB SSF03 1 0C B3...

Page 4: ...T touch electrical parts with wet hands Do NOT use in an explosive atmosphere Avoid explosive gas explosive dust etc Lower cover and guard Install the optional lower cover or guard in order to prevent...

Page 5: ...yor Secure the conveyor to the floor ground When using the conveyor be sure to secure it to the floor ground with anchor bolts etc to prevent it from toppling irrespective of indoor use or outdoor use...

Page 6: ...CHINE When working close to the conveyor take care not to get caught in it There is a risk of being injured by the conveyor DO NOT OPERATE WITHOUT GUARDS IN PLACE Do NOT remove safety covers etc There...

Page 7: ...7 2 COMPONENT NAMES HEAD DRIVE TYPE CENTER DRIVE TYPE...

Page 8: ...Position of Frame Support 3 ASSEMBLY 1 Install full length of frame straight not bent in any place 2 Finely adjust conveyor level NOTE If conveyor is bent or not level on top belt may stray to one si...

Page 9: ...connectors In this case be sure to reinstall control unit cover If control unit is delivered in separate packaging install it as follows Control unit consists of main body and attachment bracket in th...

Page 10: ...sure to confirm that the power source voltage is within the rated voltage range before NOTE 1 turning ON the power source 2 Be sure to start and stop the conveyor with RUN STAND BY switch When starti...

Page 11: ...it NOTE Do not start and stop the conveyor excessively frequently It may cause machine failure or shorten NOTE its service life NOTE 1 Be sure to ground earth NOTE 2 AC line filter should be set up by...

Page 12: ...Do not start and stop 1 the conveyor excessively frequently It may cause machine failure or shorten its service 1 life 3 The RUN STAND BY switch of control unit is not for turning the power on and of...

Page 13: ...te belt expansion percentage 1 Slacken belt 2 Mark any two points on belt surface and measure 2 length between them 3 Take up belt 4 Measure length between two marks 1 again eg 1000 mm 1 1002 mm Belt...

Page 14: ...ent in any place If necessary correct frame condition to solve belt deviation NOTE This machine is not equipped with belt alignment adjustment mechanism 6 BELT ALIGNMENT ADJUSTMENT 7 BELT REPLACEMENT...

Page 15: ...er Slacken belt See p 13 Remove C form fixing ring with a pair of snap pin pliers special tool for C form fixing ring of shaft Pull out squeezing pulley Head or Tail Pulley Removal Remove drive cover...

Page 16: ...lley See p 15 Remove hexagon nuts 4 nuts while retaining cross recessed flush head machine screws with Phillips type screwdriver Pull out motor 10 DRIVE UNIT RELOCATION possible for CENTER DRIVE TYPE...

Page 17: ...ent 5 Conveyor will not start running unless belt is pulled 1 Belt has been taken up too much 2 Belt has something sticky on undersurface 3 Belt has excessive resistance to winding Incorrect belt has...

Page 18: ...n loose attachment bolts Overheat abnormal noise Manual check and listening Inspection and adjustment or replacement Six monthly Drive pulley Wear of surface rotation malfunction Visual inspection and...

Page 19: ...19 MEMO...

Page 20: ...3 02 Particular attention is given to the manufacture and transportation of SANKI conveyors However if you need any information about the use or failure of the machine or any other matters please cont...

Reviews: