background image

10 

 

 

 

   
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUNNING THE CONVEYOR 

4-1. BE SURE TO GROUND MACHINE BEFORE OPERATION 

4-2. STARTING CONVEYOR 

  100V single-phase power source   

Ground earth terminal (green) of power cable plug. 

 

  200V single/three-phase power source   

Ground earth terminal (green) of power cable. 

NOTE: Be sure to combine controller with specified motor. Before starting conveyor, make sure that it is   

grounded. 

1. Make sure that RUN/STAND-

BY switch on control unit operating panel is in “STAND

-

BY” position. 

 

1. 

Turn on power supply and ensure that power LED (power-on indicator) is illuminated in green. 

2. Set RUN/STAND-

BY switch to “RUN” position. Motor will start rotating and conveyor wi

ll run.   

3. To increase speed, turn speed control clockwise; to decrease speed, turn it counterclockwise. Set   

1. 

appropriate speed for intended use. 

4. To stop conveyor, set RUN/STAND-

BY switch to “STAND

-

BY” position.

 

fig. Control unit operating panel 

Rotation direction switch 

Display 

Speed control 

Front panel (Tool-less removal type) 

  RUN

STAND-BY switch 

Mounting hole (It's located under 
  the front panel.) 

NOTE: 1. Be sure to confirm that the power source voltage is within the rated voltage range, before   

NOTE: 1. 

turning ON the power source. 

2. Be sure to start and stop the conveyor with RUN/STAND-BY switch. When starting and   

NOTE: 1. 

stopping the machine by external signals, use control circuit terminals on rear of inverter. (→See

 

NOTE: 1.

“Start

ing and Stop

ping the Conveyor by External Signals”, p.1

1.) 

3. When leaving the conveyor unused for a long period, make sure that the power supply is off.   

NOTE: 1.

 (The RUN/STAND-BY switch is not for turning the power on and off.) 

4. Before turning off the power supply, be sure to set RUN/STAND-

BY switch to “STAND

-

BY” 

 

NOTE: 1.

position, otherwise there is a risk that the motor will restart rotating unexpectedly when   

NOTE: 1.

powered. 

Control unit standard specification 

Applied motor 

Brushless motor 30W 

Power 
source 

Voltage 

Single-phase AC100-120V 
Single/three-phase AC200-240V 

Permissible voltage 
range 

15

  to 

10

 

Frequency 

50

60Hz 

Rated rotation speed 

3,000r/min 

Speed control range 

80

4,000r/min 

Environ- 
mental 
condition 

Ambient 
temperature 

10

  to 

40

   

(Avoid freezing.) 

Ambient humidity 

Relative humidity 85% max.   
(Avoid condensation.) 

Atmosphere 

Indoor (Avoid splash of liquids, 
corrosive/flammable gases, dust, etc.) 

Elevation 

1000m or less 

 

Summary of Contents for S-CON MINI SLIM

Page 1: ...1 S CON MINI SLIM OPERATING AND SERVICE MANUAL...

Page 2: ...manual where the machine is installed so that it may be referred to when needed TABLE OF CONTENTS 1 Caution When Handling 2 Component Names 3 Assembly 4 Running the Conveyor 5 Taking up the Belt 6 Be...

Page 3: ...ode Constant speed C Brushless motor variable speed B Motor output Code 30W 30 Code BG BW XG XW XB XX NO Specification Standard Other None Color Green White Green White Blue Other 20 JOB SSF03 1 0C B3...

Page 4: ...T touch electrical parts with wet hands Do NOT use in an explosive atmosphere Avoid explosive gas explosive dust etc Lower cover and guard Install the optional lower cover or guard in order to prevent...

Page 5: ...yor Secure the conveyor to the floor ground When using the conveyor be sure to secure it to the floor ground with anchor bolts etc to prevent it from toppling irrespective of indoor use or outdoor use...

Page 6: ...CHINE When working close to the conveyor take care not to get caught in it There is a risk of being injured by the conveyor DO NOT OPERATE WITHOUT GUARDS IN PLACE Do NOT remove safety covers etc There...

Page 7: ...7 2 COMPONENT NAMES HEAD DRIVE TYPE CENTER DRIVE TYPE...

Page 8: ...Position of Frame Support 3 ASSEMBLY 1 Install full length of frame straight not bent in any place 2 Finely adjust conveyor level NOTE If conveyor is bent or not level on top belt may stray to one si...

Page 9: ...connectors In this case be sure to reinstall control unit cover If control unit is delivered in separate packaging install it as follows Control unit consists of main body and attachment bracket in th...

Page 10: ...sure to confirm that the power source voltage is within the rated voltage range before NOTE 1 turning ON the power source 2 Be sure to start and stop the conveyor with RUN STAND BY switch When starti...

Page 11: ...it NOTE Do not start and stop the conveyor excessively frequently It may cause machine failure or shorten NOTE its service life NOTE 1 Be sure to ground earth NOTE 2 AC line filter should be set up by...

Page 12: ...Do not start and stop 1 the conveyor excessively frequently It may cause machine failure or shorten its service 1 life 3 The RUN STAND BY switch of control unit is not for turning the power on and of...

Page 13: ...te belt expansion percentage 1 Slacken belt 2 Mark any two points on belt surface and measure 2 length between them 3 Take up belt 4 Measure length between two marks 1 again eg 1000 mm 1 1002 mm Belt...

Page 14: ...ent in any place If necessary correct frame condition to solve belt deviation NOTE This machine is not equipped with belt alignment adjustment mechanism 6 BELT ALIGNMENT ADJUSTMENT 7 BELT REPLACEMENT...

Page 15: ...er Slacken belt See p 13 Remove C form fixing ring with a pair of snap pin pliers special tool for C form fixing ring of shaft Pull out squeezing pulley Head or Tail Pulley Removal Remove drive cover...

Page 16: ...lley See p 15 Remove hexagon nuts 4 nuts while retaining cross recessed flush head machine screws with Phillips type screwdriver Pull out motor 10 DRIVE UNIT RELOCATION possible for CENTER DRIVE TYPE...

Page 17: ...ent 5 Conveyor will not start running unless belt is pulled 1 Belt has been taken up too much 2 Belt has something sticky on undersurface 3 Belt has excessive resistance to winding Incorrect belt has...

Page 18: ...n loose attachment bolts Overheat abnormal noise Manual check and listening Inspection and adjustment or replacement Six monthly Drive pulley Wear of surface rotation malfunction Visual inspection and...

Page 19: ...19 MEMO...

Page 20: ...3 02 Particular attention is given to the manufacture and transportation of SANKI conveyors However if you need any information about the use or failure of the machine or any other matters please cont...

Reviews: