![SANDVIK CH420:01 Installation Manual Download Page 36](http://html1.mh-extra.com/html/sandvik/ch420-01/ch420-01_installation-manual_3886010036.webp)
3. Technical data
34
© Sandvik SRP AB – Doc. no. S 223.510 en Ver. 1
CH420:01
3.4 Lubrication system
Characteristics
CH420:01
Lubrication system
Type
Closed circuit, gravity return
System pressure
0.15–0.5 MPa (22–72 psi)
Tank mass
310 kg (680 lb)
Oil reservoir capacity
150 litres (40 US gal)
Oil type
Normally ISO VG 150
Lubrication pump
Type
Gear
Capacity
33 l/min (50 Hz)
40 l/min (60 Hz)
Number of pumps
1
Lubrication pump motor
Type
Squirrel cage
Power
1.1 kW (50Hz)
1.3 kW (60 Hz)
Speed
700 rpm (50 Hz)
840 rpm (60 Hz)
Voltage
220/380 – 240/420V (50 Hz)
250/440 – 280/480V (60 Hz)
Phases
3
Frequency
50/60 Hz
Service factor
1.00
Enclosure
TEFC
Insulation
F
Protection IP55
Frame
IEC 132
Main oil filter
Number of oil filters
1
Blocked filter sensor
Differential pressure sensor
Oil heater
Type
Electrical immersion heaters
Rating (per heater)
1.24–1.64 kW
depending on voltage
Method
Indirect heating
Numbers of heaters
2–5
Voltage
220/380 – 240/420V (50 Hz)
250/440 – 280/480V (60 Hz)
Phases
3
Frequency
50/60 Hz
Summary of Contents for CH420:01
Page 1: ...installation manual Doc no S 223 510 SANDVIK CH420 01 ...
Page 8: ...Table of contents 6 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 ...
Page 20: ...1 Introduction 18 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 ...
Page 31: ...29 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 3 Technical data ...
Page 109: ......
Page 110: ......