COMe-cTL6 – User Guide Rev. 1.7
// 44
2.6.
Environmental Specification
2.7.
Compliance
The COMe-cTL6 complies with the following standards. If modified, the prerequisites for specific approvals may no
longer apply. For more information, contact Kontron Support.
Table 52: Standards Compliance
Standard
Definition
Operating
Temperature
0°C to 60°C (for COMe-cTL6 variants)
-40°C to 85°C (by design for COMe-cTL6 E2 variants)
(PCB and components should selected and designed accordingly)
Storage
Temperature
-30°C to 85°C (for COMe- cTL6 (E1) variants)
-40°C to 85°C (for COMe- cTL6 E2 variants)
Humidity
93% relative Humidity at 40°C, non-condensing (acc. to IEC 60068-2-78)
Emission (EMC)
EN55032: 2015
Electromagnetic compatibility of multimedia equipment- Emission Requirements
Immunity (EMI)
EN 61000-6-2: 2005:
Electromagnetic compatibility (EMC) Part 6-2: Generic standards - Immunity standard
for industrial environments
Safety
(Europe)
EN 62368-1:2014
Audio/video, information and communication technology equipment - Part 1: Safety
requirements
Saftey
(USA/ Canada)
UL 62368-1/CSA 62368-1 (Component Recognition)
Recognized by Underwriters Laboratories Inc. Representative samples of this
component have been evaluated by UL and meet applicable UL requirements.
UL listings:
AZOT2.E147705
AZOT8.E147705
Shock
IEC/EN 60068-2-27
Non-operating shock – (half-sinusoidal, 11 ms, 15 g)
Vibration
IEC/EN 60068-2-6
Non-operating vibration – (sinusoidal, 10 Hz – 4000 Hz, +/- 0.15 mm, 2 g)
RoHS II
Directive 2011/65/EU
Restriction of the use of certain hazardous substances in electrical and electronic
equipment