Table 57: Dual Stage Watchdog Timer- Time-out Events 

Status  Events 

Definition 

0000b  No action 

The stage is off and will be skipped. 

0001b 

Reset 

A reset restarts the module and starts a new POST and operating system. 

0010b   NMI 

A non-maskable interrupt (NMI) is a computer processor interrupt that cannot be 
ignored by standard interrupt masking techniques in the system. It is used typically 
to signal attention for non-recoverable hardware errors. 

0011b  

SMI 

A system management interrupt (SMI) makes the processor entering the system 
management mode (SMM). As such, specific BIOS code handles the interrupt. The 
current BIOS handler for the watchdog SMI currently does nothing. For special 
requirements, contact Kontron Support. 

0100b 

SCI 

A system control interrupt (SCI) is a OS-visible interrupt to be handled by the OS 
using AML code. 

0101b 

Delay -> No 
action* 

Might be necessary when an operating system must be started and the time for the 
first trigger pulse must be extended. Only available in the first stage. 

1000b 

WDT Only 

This setting triggers the WDT pin on the baseboard connector (COM Express®  
pin B27) only. 

1001b 

Reset + WDT 

 

1010b 

NMI + WDT 

 

1011b 

SMI + WDT 

 

1100b 

SCI + WDT 

 

1101b 

DELAY + WDT 
-> No action* 

 

 

3.9.1.

 

WDT Signal 

Watchdog time-out event (pin B27) on COM Express® connector offers a signal that can be asserted when a 
watchdog timer has not been triggered with a set time. The WDT signal is configurable to any of the two stages. After 
reset, the signal is automatically deasserted. If deassertion is necessary during runtime, ask Kontron Support for 
further help. 

 

Summary of Contents for Kontron COMe-cTL6

Page 1: ...USER GUIDE www kontron com 1 COMe cTL6 User Guide Rev 1 7 Doc ID 1068 0490...

Page 2: ...COMe cTL6 User Guide Rev 1 7 www kontron com 2 This page has been intentionally left blank...

Page 3: ...ble for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions which may no...

Page 4: ...responsible to ensure that your systems and any Kontron hardware or software components incorporated in your systems meet all applicable requirements Unless otherwise stated in the product documentati...

Page 5: ...s For contact information refer to the corporate offices contact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http...

Page 6: ...ribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Page 7: ...before performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be discon...

Page 8: ...oduct then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental M...

Page 9: ...uct Specification 17 2 1 Module Variants 17 2 1 1 Commercial Grade Modules 0 C to 60 C 17 2 1 2 Extended Temperature Grade Modules E1 25 C to 75 C 17 2 1 3 E2 Modules E2 40 C to 85 C 18 2 2 Accessorie...

Page 10: ...38 2 4 4 Power Supply Modes 39 2 4 5 Single Supply Mode 40 2 5 Thermal Management 41 2 5 1 Heatspreader and Active or Passive Cooling Solutions 41 2 5 2 Active or Passive Cooling Solutions 41 2 5 3 Op...

Page 11: ...4 1 Main Setup Menu 75 6 4 2 Advanced Setup Menu 77 6 4 3 Chipset Menu 89 6 4 4 Security Setup Menu 98 6 4 5 Boot Menu 100 6 4 6 Save and Exit Setup Menu 101 7 Technical Support 102 7 1 Warranty 102...

Page 12: ...ontrol Settings 38 Table 48 ATX mode settings 39 Table 49 Single Supply Mode Settings 40 Table 50 Heatspreader Test Temperature Specifications 41 Table 51 Onboard Fan Connector 43 Table 52 Standards C...

Page 13: ...port article number 36030 0000 18 2 45 Figure 10 MTBF De rating Values Reliability report article number 36031 1600 18 7 46 Figure 11 Module Dimensions 47 Figure 12 Module Height 48 Figure 13 Heatspre...

Page 14: ...tness The COMe cTL6 is ideally suited as a powerful successor for existing solutions as it takes over their pin assignment and feature implementation Typical applications include communication digital...

Page 15: ...ess specification defines the COM Express module form factor pinout and signals The COM Express document is available at the PICMG website 1 4 COM Express Functionality All Kontron COM Express basic a...

Page 16: ...standardization allows designers to create a single system baseboard that can accept present and future COM Express modules The baseboard designer can optimize exactly how each of these functions imp...

Page 17: ...COMe cTL6 i7 1185G7E COM Express compact pin out type 6 Computer on Module with Intel Core i7 1185G7E 4x 1 8 GHz DDR4 SO DIMM Socket 36030 8000 15 5 COMe cTL6 i5 1145G7E 8 GB COM Express compact pin...

Page 18: ...2 2 GHz DDR4 SO DIMM Socket industrial temperature grade 2 2 Accessories Accessories are either COMe cTL6 product specific COMe Type 6 specific or general accessories Table 4 Product Accessories Part...

Page 19: ...ble 7 Memory Part Number Memory Description 97020 3232 CTL6 DDR4 3200 SODIMM 32GB_CTL6 Memory for Computer on Module COMe cTL6 min specification DDR4 3200 32 GB 260P 1600 MHz PC4 3200 SODIMM validated...

Page 20: ...On request 6x without Ethernet up to 8x without Ethernet SATA 1 x4 PCIe 4 0 on PEG Lanes 0 3 USB 4x USB 3 1 incl USB 2 0 4x USB 2 0 Serial 2x serial interface RX TX only Audio High Definition Audio i...

Page 21: ...COMe cTL6 User Guide Rev 1 7 www kontron com 21 2 3 2 Block Diagram The following figure displays the system block diagram applicable to all COMe cTL6 modules Figure 2 Block Diagram COMe cTL6...

Page 22: ...com 22 2 3 3 Front View Figure 3 Front View COMe cTL6 1 SoC Processor 2 DDR4 memory down 3 1xS0 DIMM DDR4 slot 4 Embedded Controller 5 NVME Mass Storage 6 Ethernet MAC PHY Intel I255 7 eDP to LVDS br...

Page 23: ...3 4 Rear View Figure 4 Rear View COMe cTL6 1 DDR4 memory down 2 2x COMe Connectors 3 Fan Connector 4 XDP Connector optional 5 Programming Connector for embedded Controller 6 SPI Flash 7 Second SPI Fla...

Page 24: ...cessing cores up to 96 graphics execution units Supports DDR4 and LPDDR4x with optional In Band ECC Configurable 12 15 28 watt thermal design points in a single SKU Up to 96 graphics execution units f...

Page 25: ...ntel Iris Xe Graphics 80 EU 4x4k or 2x8k Displays 2 VDBOX Intel UHD Graphics 48 EU 4x4k or 1x8k Displays 1 VDBOX Max Memory Size 64 GB 64 GB 64 GB 64 GB 64 GB 64 GB 64 GB 1 within Tjunction limits the...

Page 26: ...e Table 7 2 3 7 Graphics 2 3 7 1 Display Resolution The following table lists the maximum display resolutions at a set frequency and bit per pixel bpp for the supported display interfaces Table 11 Dis...

Page 27: ...CTRLCLK DDI3_CTRLDATA_AUX TCP2_AUX_N DDP3_CTRLDATA DDI3_DDC_AUX_SEL Connected to DP AUX Conversion DDI3_HPD DDSP_HPD3 2 3 7 3 LVDS with option to overlay eDP LVDS is implemented by NXP PTN3460 eDP to...

Page 28: ...supports a maximum of 12 HSIO lanes Table 18 General Purpose PCI Express 3 0 COMe connector HSIO Port Lane Config PCIE0 PCIE 5 x1 x2 x4 PCIE1 PCIE 6 x1 PCIE2 PCIE 7 x1 x2 PCIE3 PCIE 8 x1 PCIE4 PCIE 9...

Page 29: ...SB6 USB2_7 USB7 USB2_8 Note Intel starts counting USB Ports with 1 while COMe Specification starts counting with 0 Table 22 USB Overcurrent COMe connector PCH USB_12_OC USB_1234_OC_RC USB_34_OC USB_12...

Page 30: ...that s available on the baseboard too By default the EEPROM is available on address 0Ah 2 3 15 COMe Features The following table lists the supported COM Express features Table 25 COM Features SPI Boot...

Page 31: ...ternal user accessible I2C I2C_EXT Devices connected to the external I2C A0h Module Embedded EEPROM JIDA EEPROM AEh carrier EEPROM optional 64h external RTC optional This I2C bus is available at COMe...

Page 32: ...er FET switch disconnects the module SMB from the carrier during boot up After BIOS has finished configuration of the on board devices it asserts EN_SMB_EXT to close the switch Table 31 SMB Alert Sign...

Page 33: ...ed through CPLD 2 3 25 Power Button PWRBTN Table 36 Power Button PWRBTN COMe Signal PCH Description PWRBTN GPD3 PWRBTN Power button input from carrier passed through CPLD 2 3 26 Batlow Table 37 Batlow...

Page 34: ...arrier boot from SPI It can be configured by pin A34 BIOS_DIS 0 and pin B88 BIOS_DIS_ 1 in following configuration Table 41 External BIOS ROM Support For additional safety a second on module SPI flash...

Page 35: ...7 2 3 33 External Fan support Table 45 External Fan Control COMe Signal HWM Pin Description FAN_PWMOUT FANCTL2 Gated by CPLD signal FAN_PWM_ENABLE to disconnect in states other than S0 FAN_TACHIN FAN...

Page 36: ...ontron COMe CPLD Specification 2 8 VHDL block KCPLD KCPLD is connected to TGL eSPI interface to provide several features to the module carrier LPC Bus I2C UART optional GPIO Watchdog Moreover the EC i...

Page 37: ...and ATX power supply mode Industrial temperature grade modules are validated for 12 V power supply only Commercial temperature grade modules support the wide range 8 5 V to 20 V power supply 5 V Stan...

Page 38: ...he system will apply S0iX state instead of S3 and S4 This technology achieves energy savings through processor measures The amount of savings is determined by the whole system layout and might differ...

Page 39: ...supply controls enables the COMe cTL6 to operating in either ATX power mode or in single power supply mode 2 4 4 1 ATX Mode To start the module in ATX mode connect VCC and 5V Standby from a ATX PSU As...

Page 40: ...igh open reconnecting VCC x Signals are not relevant for the specific power state It makes no difference if the signal is connected or open All ground pins must be connected to the carrier board s gro...

Page 41: ...on the COM Express application and environmental conditions Active or passive cooling solutions provided from Kontron for the COMe cTL6 are usually designed to cover the power and thermal dissipation...

Page 42: ...temperature sensor in CPU can be read out from HW monitor via Platform Environment Control Interface PECI temperature sensor in NVMe can be read out from OS optional temperature sensor in SO DIMM dep...

Page 43: ...M It is clipped at 12 V 10 across the whole input range of the module to prevent Fan damage at higher voltages The maximum supply current to the fan connected to the on module fan connector is 350 mA...

Page 44: ...2 2015 Electromagnetic compatibility of multimedia equipment Emission Requirements Immunity EMI EN 61000 6 2 2005 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity standard for ind...

Page 45: ...cle number 36030 0000 18 2 System MTBF hours 504068h 40 C for COMe cTL6 E2 i7 1185GRE Reliability report article number 36031 1600 18 7 The MTBF estimates values assume no fan but a passive heat sinki...

Page 46: ...COMe cTL6 User Guide Rev 1 7 www kontron com 46 Figure 10 MTBF De rating Values Reliability report article number 36031 1600 18 7...

Page 47: ...TL6 User Guide Rev 1 7 www kontron com 47 2 8 Mechanical Specification 2 8 1 Dimensions The dimensions of the module are 95 0 mm x 95 0 mm 3 75 x 3 75 Figure 11 Module Dimensions All dimensions shown...

Page 48: ...cification defines a module height of approximately 13 mm from module PCB bottom to heatspreader top Figure 12 Module Height 1 Heatspreader 2 Heatspreaader standoff s 3 Module PCB 4 Carrier Board PCB...

Page 49: ...ware and software solution that includes an embedded hardware security module and a software framework to provide full protection for your application The COMe cTL6 includes an integrated security mod...

Page 50: ...a current of 6 A If the module is powered by the mains supply the RTC voltage is generated by on module regulators to reduce the RTC current draw 3 6 Serial Peripheral Interface SPI The Serial Periphe...

Page 51: ...he network the hashes are sent to a server that verifies that they match the expected values If any of the hashed components have been modified since the last start the match fails and the system cann...

Page 52: ...ently does nothing For special requirements contact Kontron Support 0100b SCI A system control interrupt SCI is a OS visible interrupt to be handled by the OS using AML code 0101b Delay No action Migh...

Page 53: ...S AEh 57h Carrier board EEPROM Option 64h 32h External RTC Option 4 2 System Management SM Bus The 8 bit SMBus address uses the LSB bit 0 for the direction of the device Bit0 0 defines the write addre...

Page 54: ...corresponding connectors on the carrier board and secured using the mounting points and standoffs The height of the standoffs either 5 mm or 8 mm depends on the height of the carrier board s connector...

Page 55: ...I O 3 3 Bi directional 3 3 V I O Signal O 3 3 3 3 V Output I O 5T Bi dir 3 3 V I O 5 V Tolerance O 5 5 V Output I O 5 Bi directional 5V I O Signal DP I O Differential Pair Input Output I 3 3 3 3 V Inp...

Page 56: ...chip vendors Table 61 Connector X1A Row A Pin Assignment A1 A110 Pin Signal Description Type Termination Comment A1 GND Power Ground PWR GND A2 GBE0_MDI3 Ethernet Media Dependent Interface 3 DP I O A3...

Page 57: ...BIOS_DIS0 ESPI _SAFS BIOS Selection Strap 0 I 3 3 PU 10k 3 3V S5 A35 THRMTRIP Thermal Trip O 3 3 PU 10k 3 3V S0 Thermal Trip Event transition to S5 indicator A36 USB6 USB 2 0 Data Pair Port 6 DP I O...

Page 58: ...TX2 PCI Express Lane 2 Transmit DP O A62 PCIE_TX2 PCI Express Lane 2 Transmit DP O A63 GPI1 General Purpose Input 1 I 3 3 PU 100k 3 3V S0 A64 PCIE_TX1 PCI Express Lane 1 Transmit DP O A65 PCIE_TX1 PCI...

Page 59: ...0MHz A90 GND Power Ground PWR GND A91 SPI_POWER 3 3V Power Output Pin for external SPI flash O 3 3 100mA max A92 SPI_MISO SPI Master IN Slave OUT I 3 3 PU 20k 30 in PCH S5 All SPI signals are tri stat...

Page 60: ...erial Port 1 RXD I 5T PU 10k 3 3V S0 20V protection circuit implemented on module A103 LID LID Switch Input I 3 3 PU 47k 3 3V S5 20V protection circuit implemented on module A104 VCC_12V Main Input Vo...

Page 61: ...Data 3 eSPI Master Data I O 3 I O 3 3 eSPI I O 1 8 PU 20k 3 3V S0 B8 LPC_DRQ0 ESPI_ALERT0 LPC Serial DMA Master Request 0 eSPI Alert 0 I 3 3 eSPI I 1 8 PU 10k 3 3V S0 B9 LPC_DRQ1 ESPI_ALERT1 LPC Seri...

Page 62: ...4 25k to 24 8k in PCH B37 USB7 USB 2 0 Data Pair Port 7 DP I O PD 14 25k to 24 8k in PCH B38 USB_4_5_OC USB Overcurrent Indicator Port 4 5 I 3 3 PU 10k 3 3V S5 B39 USB5 USB 2 0 Data Pair Port 5 DP I O...

Page 63: ...PCI Express Wake Event I 3 3 PU 10k 3 3V S5 B67 WAKE1 General Purpose Wake Event I 3 3 PU 10k 3 3V S5 B68 PCIE_RX0 PCI Express Lane 0 Receive DP I B69 PCIE_RX0 PCI Express Lane 0 Receive DP I B70 GND...

Page 64: ...ata Channel Clock nc B96 VGA_I2C_DATA Display Data Channel Data nc B97 SPI_CS SPI Chip Select O 3 3 B98 RSVD Reserved for future use nc B99 RSVD Reserved for future use nc B100 GND Power Ground PWR GN...

Page 65: ...2 DP I C10 USB_SSRX2 USB Super Speed Receive 2 DP I C11 GND Power Ground PWR GND C12 USB_SSRX3 USB Super Speed Receive 3 DP I C13 USB_SSRX3 USB Super Speed Receive 3 DP I C14 GND Power Ground PWR GND...

Page 66: ...46 DDI3_PAIR2 DDI3 Pair 2 DP O C47 DDI3_PAIR2 DDI3 Pair 2 DP O C48 RSVD Reserved for future use nc C49 DDI3_PAIR3 DDI3 Pair 3 DP O C50 DDI3_PAIR3 DDI3 Pair 3 DP O C51 GND Power Ground PWR GND C52 PEG_...

Page 67: ...Power Ground PWR GND C88 PEG_RX11 PEG Lane 11 Receive nc C89 PEG_RX11 PEG Lane 11 Receive nc C90 GND Power Ground PWR GND C91 PEG_RX12 PEG Lane 12 Receive nc C92 PEG_RX12 PEG Lane 12 Receive nc C93 GN...

Page 68: ...mit 2 DP O D10 USB_SSTX2 USB Super Speed Transmit 2 DP O D11 GND Power Ground PWR GND D12 USB_SSTX3 USB Super Speed Transmit 3 DP O D13 USB_SSTX3 USB Super Speed Transmit 3 DP O D14 GND Power Ground P...

Page 69: ...uture use nc D49 DDI2_PAIR3 DDI2 Pair 3 DP O D50 DDI2_PAIR3 DDI2 Pair 3 DP O D51 GND Power Ground PWR GND D52 PEG_TX0 PEG Lane 0 Transmit DP O D53 PEG_TX0 PEG Lane 0 Transmit DP O D54 PEG_LANE_RV Not...

Page 70: ...round PWR GND D91 PEG_TX12 PEG Lane 12 Transmit nc D92 PEG_TX12 PEG Lane 12 Transmit nc D93 GND Power Ground PWR GND D94 PEG_TX13 PEG Lane 13 Transmit nc D95 PEG_TX13 PEG Lane 13 Transmit nc D96 GND P...

Page 71: ...til reset is deasserted A33 HDA SDOUT HD Audio Serial Data Out O 3 3 PD 20k in PCH Flash Descriptor B47 ESPI_UN Enable Disable ESPI Mode I 3 3 A34 BIOS_DIS0 ESPI _SAFS BIOS Selection Strap 0 I 3 3 PU...

Page 72: ...een POST messages or splash screen 3 Press the DEL key 4 If the UEFI BIOS is password protected a request for password will appear Enter either the User Password or Supervisor Password press RETURN an...

Page 73: ...ot option by default 6 2 1 1 Entering the UEFI Shell To enter the UEFI Shell follow the steps below 1 Power on the board 1 Press the F7 key instead of DEL to display a choice of boot devices 2 Choose...

Page 74: ...y the startup script to the flash use the kBootScript UEFI Shell command In case there is no mass storage device attached the startup script can be generated in a RAM disk and stored in the SPI boot f...

Page 75: ...Screen Description BIOS Information Read only field Displays BIOS Information BIOS vendor Core version Compliancy Kontron BIOS Version and Access level FSP Information Read only field Displays FSP Inf...

Page 76: ...CPLD Rev Additional information for MAC Address The MAC address entry is the value used by the Ethernet controller and may contain the entry Inactive Ethernet chip is inactive Activate the Ethernet ch...

Page 77: ...ons Sub Screen Function Second level Sub Screen Description CPU Configuration Read only field CPU Information Type ID Speed L1 Data Cache L1 Instruction Cache L2 Cache L3 Cache L4 Cache VMX SMX TXT C6...

Page 78: ...for all cores all the time Enabled Disabled HwP Autonomous EPP Grouping Autonomous will not necessarily request same values for all cores with same EPP Enable Disabled EPB override over PECI Enable b...

Page 79: ...25 PL1 28 0W Power Limit 1 2 0 Power Limit 1Time Window 0 ConfigTDP Turbo Activation 0 Custom settings Down ConfigTDP Level1 Ratio 11 TAR 14 PL1 15 0W Power Limit 1 2 0 Power Limit 1 Time Window 0 Co...

Page 80: ...uency is not limited Enabled Disabled PCH FW Configuration Firmware Update Configuration Me FW Image Re Flash Enabled Disabled FW Update Enabled PTT Configuration TPM Device Selection dTPM Extended CS...

Page 81: ...est PS2 Keyboard and Mouse Enabled Disabled Power Loss Notification Feature Enabled Disabled Intel Trusted Device Setup Boot Enabled Disabled PMC Fast Boot Enabled Disabled AMT Configuration USB Provi...

Page 82: ...tion Auto 640x480 800x600 1024x768 BCLK Configuration BCLK Source Config Selects which BCLK configuration to use CPU BCLK PCH BCLK BCLK RFI Frequency SAGV Low Frequency in 10 KHz increments range 0 MH...

Page 83: ...chnology Enable exposes CPPC V2 interface to allow for hardware controlled P states Enabled Disabled Intel SpeedStep Enable allows more than two frequency ranges to be supported Enabled Disabled Hyper...

Page 84: ...test might not support 1 3 1 2 1 3 TPM 2 0 Interface Type TIS Device Select Auto supports both with the default set to TPM 2 0 TPM 1 2 TPM 2 0 Auto ACPI settings ACPI Auto Configuration Enables or di...

Page 85: ...us device from OS Normal visible Hidden Normal CPLD device ACPI mode Hidden hides CPLD device from OS Normal visible Hidden Normal SPI lines active Chooses whether SPIO or GSPIO lines are routed throu...

Page 86: ...ns at 100 at TJmax 10 C 50 Reference Temperature Determines the temperature source for automatic fan control Module Temperature CPU Temperature 5 0V Standby 4 57 V Batt Volt at COMe Pin 2 92 V Widerra...

Page 87: ...able keeps USB devices available only for EFI applications Enabled Disabled Auto XHCI Hand off Known work around for OSes without XHCI hand off support The XHCI ownership change should be claimed by X...

Page 88: ...ion RAM Disk Configuration Disk Memory Type Specifies type of memory to use from available memory pool in system to create a disk Boot Service Data Reserved Create raw Size Hex The valid RAM disk size...

Page 89: ...not be disabled for usage in an operating system because it uses a PCI root function which would cause all serial interfaces to disappear if being disabled So though being set to disabled it will be...

Page 90: ...Memory RC Version Memory Speed Memory Timings for Controller Channel Slot Size Number of Ranks and Manufacturer Override Performance Downgrade for Mixed Memory Enable override to remove performance li...

Page 91: ...Disabled Enabled GTT Size Selects the GTT Size 2 MB 4 MB 8 MB Aperture Size Selects the Aperture Size Note above 4GB MMIO BIOS assignment is automatically enabled when selecting 2048 MB aperture To u...

Page 92: ...EG60 PCI Expr Root Port 1 Control the PCIe 4 0 Root port Enabled Disabled Connection Type Selects the connection type to the root port Built in Slot ASPM4 Sets the ASPM level Disabled L1 L1 Substates...

Page 93: ...Network Accelerator GNA Device Enabled Disabled CRID Support SystemAgent CRID and TCSS CRID control for Intel SIPP Enabled Disabled WRC Feature SystemAgent WRC write cache features on IOP When enable...

Page 94: ...CIe mapping scheme 5x1 Standard Port8xh Decode PCI Express Port 8xh Decode Enabled Disabled PCIe Root Port 1 2 3 4 11 12 USB SATA PCIe Root Port 5 COMe Lane 0 PCIe Root Port 6 COMe Lane 1 PCIe Root Po...

Page 95: ...e 4 SATA and RST Configuration SATA Controller Enabled Disabled SATA Mode Selection AHCI SATA Speed Limit Auto 1 5 Gb s 3 0 Gb s 6 Gb s Software Feature Mask Configuration HDD Unlock Enable indicates...

Page 96: ...ck enable Note Enable required for SMM protection of Flash Enabled Disabled Force unlock on all GPIO pads Select enable to forces all GPIO pads to be in unlocked state Enabled Disabled HD Audio Subsys...

Page 97: ...Redirection Controls where the port 80h cycles are sent LPC Bus PCIE Bus Enhance Port 80h LPC Decoding Supports the word dword decoding of port 80h behind LPC Enabled Disabled Legacy IO Low Latency S...

Page 98: ...ption Administrator Password Sets administrator password User Password Sets user password Secure Boot Secure Boot When enabled Platform key PK is enrolled and the system is in user mode The mode chang...

Page 99: ...is limited and requested when entering the setup If only the user s password is set then the password is a power on password and must be entered to boot or enter setup In the setup the user has admini...

Page 100: ...le 72 Boot Menu Functions Function Description Boot Configuration Setup Prompt Timeout Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State O...

Page 101: ...card Changes and Exit Exits system setup without saving changes Save Changes and Reset Resets system after saving changes Discard Changes and Reset Resets system setup without saving changes Save Chan...

Page 102: ...Addition connected hardware full description of hardware set up The serial number can be found on the Type Label located on the product s rear side Be ready to explain the nature of your problem to th...

Page 103: ...or Kontron Europe GmbH and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the product identification Information Name of product...

Page 104: ...ble Unit Gb Gigabit GBE Gigabit Ethernet GPI General Purpose Input GPIO General Purpose Input Output GPO General Purpose Output GPU Graphics Processing Unit HBR2 High Bitrate 2 HDA High Definition Aud...

Page 105: ...mall Outline Dual in line Memory Module SOIC Small Outline Integrated Circuit SOL Serial Over LAN SPI Serial Peripheral Interface SSH Secure Shell TPM Trusted Platform Module UART Universal Asynchrono...

Page 106: ...tandard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result c...

Reviews: