(32) 1200 PSI Hard Surface Extractor
1200 PSI Hard Surface Extractor (9)
Figure 2: Metering Tip Dilution Ratios
Tip Color
Concentrated
Dilution Ratio
(oz./gal.)
Liquids Powders
Tan
0.30
---
Orange
0.40
---
Turquoise
0.50
---
Pink
0.75
---
Clear
1.00
---
Brown
1.12
---
Red
1.50
---
White
1.75
---
Green
2.00
0.25
Blue
2.50
0.30
Yellow
3.75
0.47
Black
5.00
0.63
Purple
8.50
1.06
Gray
11.50
---
None
16.25
---
Setup:
inside the solution tank is a
bottle float. Check the chemical feed
supply foot valve for debris and clean
if necessary. Insert the line into the
cleaning concentrate so that it touches
the bottom of the bottle. Set cleaning
concentrate on the machine or inside the
fresh water solution tank opening.
Connect the fill hose to the quick
disconnect located on the back of the
machine. Attached the water supply
hose to any available faucet. It may
require adapters to fit the various faucet
combinations you will encounter. Never
force a threaded fitting. Place a towel
over the faucet connection so that any
spray will be controlled. Turn on the
water and check the hose connections
for leaks.
The solution tank will fill approximately
half full (about 5-gallons). As the tank
is filling, cleaning concentrate is being
drawn into the solution tank.
Shutdown:
before the end of each job, turn off the water supply to prevent the solution
tank from becoming completely full. With the cleaning completed and the solution pump
turned off, disconnect the fill hose from the faucet, drain the water in the fill hose back
into the solution tank and remove the fill hose. Remove the chemical feed supply tube
from the chemical solution jug, clean the filter and place into the solution tank. Vacuum
out the solution tank and clean the solution tank water filter.
4.0 Prepare Unit for Use Continued
4.1 Automatic Chemical Feed Continued
Metering Tip Replacement CONTINUED:
Unscrew the colored metering tip and
replace with the tip that corresponds to the portable dilution ratio for your cleaning
product (Figure 2).Reconnect the plastic supply tube.
Liquid Concentrates:
the Hard Surface Extractor comes with the orange metering
tip installed at the factory. This tip is rated for a 0.4 oz. of chemical per gallon of water,
which is a standard dilution ratio for the most popular liquid cleaning products on the
market. Refer to your product’s dilution ratio for portable extractors and select the proper
metering tip from the chart displayed in Figure 2.
Fresh Water Rinse:
for fresh water rinsing, simply leave the chemical supply tube in
the solution tank.
Manual Filling:
to use the Hard Surface Extractor without the automatic filling system,
simply pre-mix your solution.
11.0 Base with Vacuum Components Schematic
Drawing
https://harrissupplyind.com - To Order Parts Call 608-268-8080