(10) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (31)

4.0   Prepare Unit for Use Continued

4.2    Pressure Pump System

The Hard Surface Extractor utilizes a twin piston pump which is adjustable from 100-

1200 PSI. Never operate the pump at a pressure setting over 1200 PSI or without water 

in the solution tank. Doing so will damage the pump and will void the warranty. Anytime 

the Hard Surface Extractor has been stored for a period of time or has had the pump run 

“dry,” the solution pump will have to be primed to remove air which might be trapped in 

the pumping system (see “Priming the Solution Pump” section).
When high pressure drop is engaged, a pressure drop of approximately 100 PSI is 

considered normal. However, if pressure drops greatly exceeding 100 PSI or if there is 

strong pulsation in the solution hose, prime the pump.

Pressure Regulator (Unloader Valve):

 pressure is easily adjusted by a pressure 

regulator located on the rear of the machine next to the pressure gauge, only when the 

valve to a wand or high pressure valve is engaged. To increase the solution pressure, twist 

the regulator handle clockwise. DO NOT operate the pump above 1200 PSI. 

Priming the Solution Pump:

 connect the pressure hose to the female quick 

disconnect (QD) on the front of the machine. Insert an open-ended male QD into the 

female QD on the end of the pressure hose.
Turn on the pressure pump switch and the vacuum switches (both vacuum I and II 

switches). Direct the solution back into the recovery tank through the vacuum inlet. Cup 

your hand around the vacuum inlet allowing the vacuum from the Hard Surface Extractor 

to pull the solution through the solution hose. Allow solution to run for 10 seconds. This 

allows the solution to push out any air in the pumping system. Repeat this procedure if 

necessary. When the pressure hose is connected to the wand, the pressure drop should 

only be approximately 100 PSI.

4.3    Vacuum System

Vacuum Motors:

 the Hard Surface Extractor utilizes a unique two (2) vacuum system, 

using one (1) 3-stage and one (1) 2-stage motor, which produces both outstanding 

vacuum lift and airflow for superior extraction and drying times. The vacuum system can 

be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for 

carpet cleaning, water extraction and hard surface cleaning.

Automatic Vacuum Shut-Off:

 The float assembly shut-off, located in the recovery 

tank on the vacuum stand pipe, prevents the waste tank from overflowing into the stand 

pipe and damaging the vacuum motors. The float assembly will cut-off vacuum to the 

waste tank. When this happens, immediately turn off the vacuum motors and empty the 

waste tank. If the operator continues to use machine after the tank is full, it will void the 

Warranty. The float assembly has a filter to prevent lint and debris from entering the stand 

pipe. Refer to the “Maintenance” section for removal and proper cleaning.

Recovery Tank:

 the vacuum system requires the use of an external filter. The clear 

view in-line filter is included with the machine and must be used on every job.
It is also necessary to use a defoamer to eliminate foam build-up in the recovery 

tank which could lead to foam/moisture entering the vacuums and contributing to 

early failure of the vacuum motors.If moisture does enter the vacuum motors, contact 

an authorized service center. To prevent moisture from damaging the vacuum motors 

during storage, empty the recovery tank and store with the lid open.

10.0   Recovery Tank Parts List

Drawing No.

Item No.

Description

Quantity

12

10-0419-A

Screw for Extractor Hatch

6

13

10-0804

Hatch Cover

1

14

10-0804-A

Hatch Cover Gasket

1

15

80-0101

3/4” Check Valve

1

16

80-0100

3/4” Hose x 3/4” MNPT

1

17

80-0100

3/4” GHT Cap

1

18

10-0820

End Cap for Hinge

2

19

10-0821

Extractor Hinge

2

20

10-0830

Hinge Keeper

2

21

10-0805

Dump Valve

1

22

80-0011-2

90 Degree Street Elbow

2

23

80-0004

1/4” x 4” Brass Nipple

1

24

80-0032

3/8” Bulk Head Fitting

1

25

80-0115-B

3/8” MPT x 1/2” Brass Barb

1

26

10-0849

1-1/2” ABS Fitting

1

27

80-0008

1.5 PVC Femal Adapter

1

28

10-0416-A

1-1/2” Black ABS Stand Pipe

1

29

80-0012

Shut-Off Assembly for Extractor

1

30

80-0105

Float Switch for Sump Pump

1

31

80-0103

Sump Pump

1

32

80-0108

3/4” Bard x 3/4” SFGHT

1

33

80-0113

1” Hose Clamp

2

34

80-0106

3/4” Hose for Auto-Dump

1

35

80-0102

3/4” MNPT x 3/4” Barb

1

36

10-0806

1-1/2” Grey Hose Bard Fitting

1

37

80-0101

3/4” Check Valve

1

38

80-0104

Strain Relief for Sump Pump

2

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 80-5000

Page 1: ...e for two 2 years from the original date of sale and the pump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...nnection of Solution Hose 13 5 4 Power Priming the High Pressure Pump 14 5 5 Connection of Vacuum Hoses 14 5 6 Connection of Auto Dump Hose 15 5 7 Adjusting the Pressure 16 5 8 Switch Panel 17 6 0 Shu...

Page 4: ...t send parts or equipment back to the manufacturer without an RMA Number and approval No labor will be paid for nor parts cost paid for or reimbursed that have not previously been approved by the manu...

Page 5: ...throughout the assembly process Prior to packaging your equipment was again inspected for assurance of flawless operation This machine is protectively packed to prevent damage in shipment We recommend...

Page 6: ...NOT leave machine outdoors in extreme heat or cold Harsh weather elements will damage components and void warranty DO NOT pick up anything that is burning or smoking such as cigarettes matches or hot...

Page 7: ...y a qualified electrician This electric equipment is for use on a normal 120 volt circuit It has a grounded plug that looks like the plug illustrated in Fig A The use of a temporary adaptor is NOT rec...

Page 8: ...rranty Chemical Metering the Hard Surface Extractor is equipped with an automatic water fill chemical feed metering system As the solution tank fills with water cleaning concentrate is drawn into the...

Page 9: ...r supply to prevent the solution tank from becoming completely full With the cleaning completed and the solution pump turned off disconnect the fill hose from the faucet drain the water in the fill ho...

Page 10: ...vacuum system can be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for carpet cleaning water extraction and hard surface cleaning Automatic Vacuum Shut Off The float...

Page 11: ...wer to operate the machine Plug the two 2 cords into two 2 outlets from different circuits 5 2 Water and Chemical Dilution Auto Fill The chemical dilution rate is controlled by the metering tip and th...

Page 12: ...y Thicker more viscous chemicals will dilute at a different rate DO NOT use powdered chemicals in the machine Use of powdered chemicals will void your warranty Contact your distributor if you have que...

Page 13: ...e to the solution outlet female QD on the front of the machine Connect the other end of the hose to the male QD on the cleaning tool When you are ready to start cleaning turn the solution pump switch...

Page 14: ...tank full 10 Float shut off filter clogged 11 Ball stuck in float shut off 12 Auto dump pump out check valve stuck open 13 Recover tank damaged 1 Replace vacuum motor 2 Replace gasket 3 Replace gasket...

Page 15: ...6 Replace pump motor 7 Repair or replace pump head and bearing check motor and or replace complete pump and motor assembly Low Solution Pressure and or Pulsation 1 Jets too large for pressure desired...

Page 16: ...n or contact your distributor for advice or assistance To increase solution pressure turn the regulator knob clockwise To decrease solution pressure turn the regulator knob counter clockwise 7 0 Maint...

Page 17: ...to the motor base Lift the tanks back onto the base and restore the latch IMPORTANT this filter must be cleaned at least once a week to prevent water blockage to the pump 7 12 Flush Chemical System Ch...

Page 18: ...ntenance procedure should be performed regardless of whether the waste pump out has been used After cleaning the recovery tank remove the cap and connect the green 3 4 x 50 foot garden hose to the aut...

Page 19: ...nk Unscrew the filter counterclockwise and rinse with fresh water If necessary use a tooth brush to remove detergent build up Note a heavy build up is a warning sign that the solution system should be...

Page 20: ...new or cleaned bag Close lid and secure latch Filter Bag Lid O Ring Latch Filter Body Vacuum Shut Off Assembly 7 0 Maintenance Continued 7 6 Clean Auto Dump Pump Out The auto dump pump out system is...