(6) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (35)

1.0   Safety Instructions Continued

Turn off all controls before unplugging. This is not a toy. Close attention is necessary 

when used around or near children. Use common sense to protect yourself and others 

from injury when using the machine and always wear the appropriate clothing and safety 

equipment when operating the unit.
•  DO NOT leave the machine when plugged in. Unplug it from the outlet when not in 

use and before servicing. 

•  DO NOT use this equipment with a damaged cord or plug. If the unit is not working 

as it should because it has been dropped, damaged, left outdoors, etc., contact an 

authorized service center.

•  DO NOT unplug the equipment by pulling the cord. To unplug, grasp the plug, not the 

cord. DO NOT pull the unit by the cord, use the cord as a handle, close a door on the 

cord, or pull the cord around sharp edges or corners. Keep the cord away from heated 

surfaces. Lift using only the appropriate handles.

•  DO NOT overstretch the safety power cord between the equipment and the electrical 

outlet in the wall.

•  DO NOT move the machine up or down stairs with fluid in the machine. Drain 

solution and recovery tanks before moving the unit up or down stairs. Use extra care 

when cleaning on stairs.

•  DO NOT handle the plug of the equipment with wet hands.
•  DO NOT expose to rain or use on wet surfaces, to avoid electric shock. Store indoors.
•  DO NOT leave machine outdoors, in extreme heat or cold. Harsh weather elements 

will damage components and void warranty.

•  DO NOT pick up anything that is burning or smoking such as cigarettes, matches or 

hot ashes.

•  DO NOT use the equipment to pick up flammable or combustible liquids such as 

gasoline or use in areas where they may be present.

•  DO NOT use where oxygen or anesthetics are used. 
•  DO NOT put objects into openings or use with any openings blocked. Keep free 

of dust, lint, hair and anything that may reduce air flow. Keep hair, loose clothing, 

fingers, and all body parts away from openings and moving parts to ensure safe 

operation.

•  DO NOT use if any hoses or nozzles are damaged, cut or punctured.
•  DO NOT allow pump to run dry. Always maintain an adequate solution level to supply 

solution pump.

•  DO NOT use Citrus Acid, Buterol or harsh degreasers inside the machine.
•  DO NOT lubricate the motor. If the motor is lubricated, this will VOID your warranty.

12.0   Base with Pump Components Parts List

Drawing No.

Item No.

Description

Quantity

58

10-0832

S/R Strap Bolts

1

59

10-0834

Pump Flat Washer

16

60

10-0831

S/R Bracket for Extractor

1

61

80-0112-UN

12-- PSI Unloader Valve / Regulator

1

62

80-0059-4

1200 PSI Extractor Gauge

1

63

10-0838

Pigtail for Extractor

2

64

10-0850

Strain Relief for Extractor Pigtail

2

65

10-0851

Strain Relief Nut for Extractor Pigtail

2

66

10-0822

Exhaust Grate

1

67

10-0835-N

Nut for Pump Bolt on Extractor

4

68

10-0835-B

Pump Bolt

4

69

10-0834

Flat Washer

4

70

80-0112

1200 PSI Pump Kit (Includes Hoses)

1

71

10-0826

3/4” Hose Clamp

2

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 80-5000

Page 1: ...e for two 2 years from the original date of sale and the pump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...nnection of Solution Hose 13 5 4 Power Priming the High Pressure Pump 14 5 5 Connection of Vacuum Hoses 14 5 6 Connection of Auto Dump Hose 15 5 7 Adjusting the Pressure 16 5 8 Switch Panel 17 6 0 Shu...

Page 4: ...t send parts or equipment back to the manufacturer without an RMA Number and approval No labor will be paid for nor parts cost paid for or reimbursed that have not previously been approved by the manu...

Page 5: ...throughout the assembly process Prior to packaging your equipment was again inspected for assurance of flawless operation This machine is protectively packed to prevent damage in shipment We recommend...

Page 6: ...NOT leave machine outdoors in extreme heat or cold Harsh weather elements will damage components and void warranty DO NOT pick up anything that is burning or smoking such as cigarettes matches or hot...

Page 7: ...y a qualified electrician This electric equipment is for use on a normal 120 volt circuit It has a grounded plug that looks like the plug illustrated in Fig A The use of a temporary adaptor is NOT rec...

Page 8: ...rranty Chemical Metering the Hard Surface Extractor is equipped with an automatic water fill chemical feed metering system As the solution tank fills with water cleaning concentrate is drawn into the...

Page 9: ...r supply to prevent the solution tank from becoming completely full With the cleaning completed and the solution pump turned off disconnect the fill hose from the faucet drain the water in the fill ho...

Page 10: ...vacuum system can be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for carpet cleaning water extraction and hard surface cleaning Automatic Vacuum Shut Off The float...

Page 11: ...wer to operate the machine Plug the two 2 cords into two 2 outlets from different circuits 5 2 Water and Chemical Dilution Auto Fill The chemical dilution rate is controlled by the metering tip and th...

Page 12: ...y Thicker more viscous chemicals will dilute at a different rate DO NOT use powdered chemicals in the machine Use of powdered chemicals will void your warranty Contact your distributor if you have que...

Page 13: ...e to the solution outlet female QD on the front of the machine Connect the other end of the hose to the male QD on the cleaning tool When you are ready to start cleaning turn the solution pump switch...

Page 14: ...tank full 10 Float shut off filter clogged 11 Ball stuck in float shut off 12 Auto dump pump out check valve stuck open 13 Recover tank damaged 1 Replace vacuum motor 2 Replace gasket 3 Replace gasket...

Page 15: ...6 Replace pump motor 7 Repair or replace pump head and bearing check motor and or replace complete pump and motor assembly Low Solution Pressure and or Pulsation 1 Jets too large for pressure desired...

Page 16: ...n or contact your distributor for advice or assistance To increase solution pressure turn the regulator knob clockwise To decrease solution pressure turn the regulator knob counter clockwise 7 0 Maint...

Page 17: ...to the motor base Lift the tanks back onto the base and restore the latch IMPORTANT this filter must be cleaned at least once a week to prevent water blockage to the pump 7 12 Flush Chemical System Ch...

Page 18: ...ntenance procedure should be performed regardless of whether the waste pump out has been used After cleaning the recovery tank remove the cap and connect the green 3 4 x 50 foot garden hose to the aut...

Page 19: ...nk Unscrew the filter counterclockwise and rinse with fresh water If necessary use a tooth brush to remove detergent build up Note a heavy build up is a warning sign that the solution system should be...

Page 20: ...new or cleaned bag Close lid and secure latch Filter Bag Lid O Ring Latch Filter Body Vacuum Shut Off Assembly 7 0 Maintenance Continued 7 6 Clean Auto Dump Pump Out The auto dump pump out system is...