(8) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (33)

4.0   Prepare Unit for Use

DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE 

INDOORS.

•  All hard surface extractors, no matter what the time of year, are shipped with 

antifreeze in the solution lines. Prior to first use, fill the solution tank with one quart 

of warm water. Attach the hose and using a hand tool or wand, flush out the system by 

spraying the one quart of water through the pump.

•  Attach the vacuum hose and the brass quick disconnect.
•  Fill the solution tank with warm water (less than 100 degrees Fahrenheit). Fill to 

approximately 4 inches from the top. Pre-spray and agitate the surface with detergent 

made for floor cleaning or upholstery. Use only warm water to extract the pre-spray 

from the surface.

•  Be sure to replace any filters back into the machine prior to use.
•  Do not use citric acid, butyl glycol or harsh degreasers inside the machine.

4.1    Automatic Chemical Feed

WARNING: THE HARD SURFACE EXTRACTOR IS DESIGNED FOR US 

WITH WATER-BASED CLEANING SOLUTIONS, SUCH AS LOW-FOAMING 

DETERGENTS OR ACID RINSES. Never use dry solvent solutions. The use of 

dry solvents in your extractor will void the warranty.

Chemical Metering:

 the Hard Surface Extractor is equipped with an automatic 

water fill/chemical feed metering system. As the solution tank fills with water, cleaning 

concentrate is drawn into the solution tank at a designated rate, via metering tip. A 

complete set of metering tips are included.

Metering Tip Replacement:

 to adjust the amount of cleaning concentrate being 

drawn, simply remove the plastic supply tube from the chemical feed metering valve 

(Figure 1). Continues on the next page.

11.0   Base with Vacuum Components Parts List

Drawing No.

Item No.

Description

Quantity

39

10-0848-B

1-1/2” 90 Degree ABS Street Elbow

4

40

80-0003-A

1-1/2” Black Lined Gray Hose

2

41

SN-12-MFLD

Extractor Motor Manifold

2

42

10-0836

19” Axle for Extractor

1

43

10-0807

Wheel for Extractor

2

44

10-0820

End Cap for Extractor Axel

2

45

10-0419-A

Screw for Extractor Hatch

6

46

10-0822

Exhaust Grate 

3

47

10-0808

Caster for Extractor

2

48

10-0816

1/4-20 - 1/2” Hex Caster Bolt

8

49

10-1030-S2

2-Stage Extractor Motor Gasket

1

50

10-0204

Motor Mount Back-Up Washer

6

51

10-0811

2-Stage Extractor Motor

1

52

10-0833-L

Manifolt Bolt 10-32 x 1/4” Hex Screw

6

53

T-A001

Cooling Duct

2

54

10-0810

3-Stage Extractor Motor

1

55

80-0116

Spacer for Extractor Motors

6

56

10-0155

Straight Hose Cuff

1

57

10-1030-S3

3-Stage Extractor Motor Gasket

1

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 80-5000

Page 1: ...e for two 2 years from the original date of sale and the pump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...nnection of Solution Hose 13 5 4 Power Priming the High Pressure Pump 14 5 5 Connection of Vacuum Hoses 14 5 6 Connection of Auto Dump Hose 15 5 7 Adjusting the Pressure 16 5 8 Switch Panel 17 6 0 Shu...

Page 4: ...t send parts or equipment back to the manufacturer without an RMA Number and approval No labor will be paid for nor parts cost paid for or reimbursed that have not previously been approved by the manu...

Page 5: ...throughout the assembly process Prior to packaging your equipment was again inspected for assurance of flawless operation This machine is protectively packed to prevent damage in shipment We recommend...

Page 6: ...NOT leave machine outdoors in extreme heat or cold Harsh weather elements will damage components and void warranty DO NOT pick up anything that is burning or smoking such as cigarettes matches or hot...

Page 7: ...y a qualified electrician This electric equipment is for use on a normal 120 volt circuit It has a grounded plug that looks like the plug illustrated in Fig A The use of a temporary adaptor is NOT rec...

Page 8: ...rranty Chemical Metering the Hard Surface Extractor is equipped with an automatic water fill chemical feed metering system As the solution tank fills with water cleaning concentrate is drawn into the...

Page 9: ...r supply to prevent the solution tank from becoming completely full With the cleaning completed and the solution pump turned off disconnect the fill hose from the faucet drain the water in the fill ho...

Page 10: ...vacuum system can be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for carpet cleaning water extraction and hard surface cleaning Automatic Vacuum Shut Off The float...

Page 11: ...wer to operate the machine Plug the two 2 cords into two 2 outlets from different circuits 5 2 Water and Chemical Dilution Auto Fill The chemical dilution rate is controlled by the metering tip and th...

Page 12: ...y Thicker more viscous chemicals will dilute at a different rate DO NOT use powdered chemicals in the machine Use of powdered chemicals will void your warranty Contact your distributor if you have que...

Page 13: ...e to the solution outlet female QD on the front of the machine Connect the other end of the hose to the male QD on the cleaning tool When you are ready to start cleaning turn the solution pump switch...

Page 14: ...tank full 10 Float shut off filter clogged 11 Ball stuck in float shut off 12 Auto dump pump out check valve stuck open 13 Recover tank damaged 1 Replace vacuum motor 2 Replace gasket 3 Replace gasket...

Page 15: ...6 Replace pump motor 7 Repair or replace pump head and bearing check motor and or replace complete pump and motor assembly Low Solution Pressure and or Pulsation 1 Jets too large for pressure desired...

Page 16: ...n or contact your distributor for advice or assistance To increase solution pressure turn the regulator knob clockwise To decrease solution pressure turn the regulator knob counter clockwise 7 0 Maint...

Page 17: ...to the motor base Lift the tanks back onto the base and restore the latch IMPORTANT this filter must be cleaned at least once a week to prevent water blockage to the pump 7 12 Flush Chemical System Ch...

Page 18: ...ntenance procedure should be performed regardless of whether the waste pump out has been used After cleaning the recovery tank remove the cap and connect the green 3 4 x 50 foot garden hose to the aut...

Page 19: ...nk Unscrew the filter counterclockwise and rinse with fresh water If necessary use a tooth brush to remove detergent build up Note a heavy build up is a warning sign that the solution system should be...

Page 20: ...new or cleaned bag Close lid and secure latch Filter Bag Lid O Ring Latch Filter Body Vacuum Shut Off Assembly 7 0 Maintenance Continued 7 6 Clean Auto Dump Pump Out The auto dump pump out system is...