(14) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (27)

5.0   Set-Up and Operation Continued 

5.4    Power Priming the High Pressure Pump

Once water is in the solution tank, the high pressure pump must be primed:
•  Turn ON both vacuums then the solution pump. The 

vacuum will pull solution through the pump and prime 

valve into the vacuum tank.

•  Place the end of priming hose inside the vacuum hose barb.
•  Cup a hand around the hose and barb to increase the 

vacuum suction on the hose. When the pump is primed, you 

will hear the pulsation of the pump change.

•  After priming, turn OFF the solution pump. If you have not 

yet connected your solution hose or tool, you may have to 

relieve the pressure in the line so you can connected your 

hose or tool.

If the pump still does not prime or if flow is low or unsteady, 

check the hose from the solution tank to the pump (as well as the filter) for clogging, 

kinks or restrictions. Clean or replace hose and/or filter and repeat the priming process.
If you are having trouble with the pump, refer to the “Trouble Shooting Guide” section or 

contact your distributor for advice or assistance.

5.5    Connection of Vacuum Hoses

There are three (3) components used to connect the cleaning tool to the vacuums and 

recovery tank:
1.  4-Foot Vacuum Hose: connected to the vacuum barb on the front of the machine and 

to the outlet side of the clear view in-line filter.

2.  Clear View In-Line Filter
3.  25-Foot Vacuum Hose:
 the 2” cuff on the 25-foot vacuum hose is connected to the 

inlet side of the clear view in-line filter The other end with the 1-1/2” cuff is connected 

to the cleaning tool.

When ready to being cleaning, turn both vacuum switches to the ON position. While 

the Hard Surface Extractor can operate with only one (1) vacuum for cleaning delicate 

fabrics, in most situations you will turn both vacuums switches to ON.

Short Vacuum Hose with Cuffs

2” x 4-Feet with 2” Cuffs

Vacuum Hose

2” x 25-Feet with 2” Cuffs

8.0   Trouble Shooting Guide Continued

Never operate the Hard Surface Extractor when the equipment is not performing as 

expected or when any part is visibly damaged. When repair is needed, take the equipment 

to an authorized service center.

Problem

Possible Cause

Remedy

Loss of Vacuum

1. 

Vacuum motor faulty

2. 

Vacuum motor gasket damaged

3. 

Recovery tank lid gasket damaged

4. 

Dump valve open

5. 

Dump valve leaking

6. 

Vacuum motor hoses loose/leaking

7. 

Vacuum hose or tool clogged

8. 

Vacuum hoses or cuffs leaking

9. 

Recovery tank full

10. 

Float shut-off filter clogged

11. 

Ball stuck in float shut-off

12. 

Auto-dump pump-out check valve 

stuck open

13. 

Recover tank damaged

1. 

Replace vacuum motor

2. 

Replace gasket

3. 

Replace gasket

4. 

Close valve

5. 

Repair or replace dump valve

6. 

Reconnect or replace vacuum motor hoses

7. 

Clean out vacuum hoses and tool

8. 

Replace vacuum hoses, cuffs and connectors as 

needed

9. 

Drain tank

10. 

Clean float shut-off filter

11. 

Repair or replace float shut-off

12. 

Clean out or replace check valve

13. 

Replace recovery tank

Chemical not 

Feeding

1. 

Solution tank not filling

2. 

Chemical hose restricted

3. 

Filter screen plugged

4. 

Low incoming water pressure

5. 

Wrong size metering tip

6. 

Chemical proportioner faulty

7. 

Check valve in filter faulty

1. 

Check and repair auto fill assembly

2. 

Un-kink, shorten, clean out or replace hose

3. 

Clean or replace filter

4. 

Set chemical bottle on top of machine – shorten 

chemical hose – find other water source

5. 

Change metering tip

6. 

Replace chemical proportioner

7. 

Replace filter

Tool won’t Spray 

–  Low or Uneven 

Spray 

1. 

Jets clogged

2. 

In-line filter clogged

3. 

Jets worn

4. 

Jets not aligned properly

5. 

Tool valve faulty

6. 

Quick disconnects or hoses restricted

1. 

Clean out or replace jets

2. 

Clean our or replace filter

3. 

Replace jets

4. 

Re-align jets

5. 

Repair or replace valve

6. 

Clean out or replace quick disconnects and/or hoses

Solution Tank not 

Filling

1. 

Water source turned off

2. 

Float not on valve arm

3. 

Float valve faulty

4. 

Water hose restricted

5. 

Quick disconnects faulty

1. 

Turn on faucet or find other water source

2. 

Reconnect float to valve arm – adjust to proper 

height/level

3. 

Repair or replace float valve

4. 

Un-kink, clean out or replace hose

5. 

Clean our or replace quick disconnects

Solution Tank 

Overflowing

1. 

Float too heavy/filled with water

2. 

Float and chain tangled

3. 

Float too high

4. 

Float valve faulty

1. 

Replace float

2. 

Make sure float chain free and hanging properly

3. 

Adjust chain to set float at proper level

4. 

Repair or replace float valve

Chemical Jug 

Filling with Water 

– Overflowing

1. 

Foot valve in filter stuck

2. 

Foot valve in filter faulty

1. 

Clean out foot valve and filter

2. 

Replace foot valve and filter

To reduce the risk of fire, electrical shock or injury, repairs to wiring should only be performed by experienced service technicians. If 

you are not experienced in checking electrical wiring, contact your nearest authorized service center to perform tests and repairs to 

wiring and switches.

Contact your distributor for additional troubleshooting assistance, to order parts or for 

advice and assistance in performing necessary repairs.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 80-5000

Page 1: ...e for two 2 years from the original date of sale and the pump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...nnection of Solution Hose 13 5 4 Power Priming the High Pressure Pump 14 5 5 Connection of Vacuum Hoses 14 5 6 Connection of Auto Dump Hose 15 5 7 Adjusting the Pressure 16 5 8 Switch Panel 17 6 0 Shu...

Page 4: ...t send parts or equipment back to the manufacturer without an RMA Number and approval No labor will be paid for nor parts cost paid for or reimbursed that have not previously been approved by the manu...

Page 5: ...throughout the assembly process Prior to packaging your equipment was again inspected for assurance of flawless operation This machine is protectively packed to prevent damage in shipment We recommend...

Page 6: ...NOT leave machine outdoors in extreme heat or cold Harsh weather elements will damage components and void warranty DO NOT pick up anything that is burning or smoking such as cigarettes matches or hot...

Page 7: ...y a qualified electrician This electric equipment is for use on a normal 120 volt circuit It has a grounded plug that looks like the plug illustrated in Fig A The use of a temporary adaptor is NOT rec...

Page 8: ...rranty Chemical Metering the Hard Surface Extractor is equipped with an automatic water fill chemical feed metering system As the solution tank fills with water cleaning concentrate is drawn into the...

Page 9: ...r supply to prevent the solution tank from becoming completely full With the cleaning completed and the solution pump turned off disconnect the fill hose from the faucet drain the water in the fill ho...

Page 10: ...vacuum system can be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for carpet cleaning water extraction and hard surface cleaning Automatic Vacuum Shut Off The float...

Page 11: ...wer to operate the machine Plug the two 2 cords into two 2 outlets from different circuits 5 2 Water and Chemical Dilution Auto Fill The chemical dilution rate is controlled by the metering tip and th...

Page 12: ...y Thicker more viscous chemicals will dilute at a different rate DO NOT use powdered chemicals in the machine Use of powdered chemicals will void your warranty Contact your distributor if you have que...

Page 13: ...e to the solution outlet female QD on the front of the machine Connect the other end of the hose to the male QD on the cleaning tool When you are ready to start cleaning turn the solution pump switch...

Page 14: ...tank full 10 Float shut off filter clogged 11 Ball stuck in float shut off 12 Auto dump pump out check valve stuck open 13 Recover tank damaged 1 Replace vacuum motor 2 Replace gasket 3 Replace gasket...

Page 15: ...6 Replace pump motor 7 Repair or replace pump head and bearing check motor and or replace complete pump and motor assembly Low Solution Pressure and or Pulsation 1 Jets too large for pressure desired...

Page 16: ...n or contact your distributor for advice or assistance To increase solution pressure turn the regulator knob clockwise To decrease solution pressure turn the regulator knob counter clockwise 7 0 Maint...

Page 17: ...to the motor base Lift the tanks back onto the base and restore the latch IMPORTANT this filter must be cleaned at least once a week to prevent water blockage to the pump 7 12 Flush Chemical System Ch...

Page 18: ...ntenance procedure should be performed regardless of whether the waste pump out has been used After cleaning the recovery tank remove the cap and connect the green 3 4 x 50 foot garden hose to the aut...

Page 19: ...nk Unscrew the filter counterclockwise and rinse with fresh water If necessary use a tooth brush to remove detergent build up Note a heavy build up is a warning sign that the solution system should be...

Page 20: ...new or cleaned bag Close lid and secure latch Filter Bag Lid O Ring Latch Filter Body Vacuum Shut Off Assembly 7 0 Maintenance Continued 7 6 Clean Auto Dump Pump Out The auto dump pump out system is...