Sandia 80-5000 Operation And Maintenance Manual Download Page 1

Copyright © 2016 Ultimate Solutions | Sandia Products

Safety, Operation and Maintenance 

Manual with Parts List

Please read before use!

1200 PSI ADJUSTABLE PUMP, DUAL MOTORS 

Important Information and Safety Instructions

Register your Machine Online or Return your Machine Warranty Card!
Serial No:                                                         

HARD SURF

ACE EXTRA

CTOR

Sniper 12-

G

allon 1200 PSI Har

d Sur

fac

e Ex

tr

ac

tor

ACTIVATE 

YOUR 

WARRANTY!

Another Innovative 

Product from

Manufactured with

Pride in the U.S.A.

Model No. 80-5000

New Equipment Warranty

Limited Warranty

Sandia Products warrants new equipment against defects in material and 
workmanship under normal use and service to the original purchaser. Any statutory 
implied warranties, including any warranty of merchantability or fitness for a 
particular purpose, are expressly limited to the duration of this written warranty. 
Sandia Products will not be liable for any other damages, including but not limited 
to indirect or special consequential damages arising out of or in connection with the 
furnishing, performance, use or inability to use the machine. This remedy shall be the 
exclusive remedy of the purchaser. The warranty period is subject to the conditions 
stated below.

Lifetime Warranty on Body, 2-Years on Vacuum Motors, 1-Year on 

Pump and all Electrical Parts, 90-Days on Tools and Accessories

Sandia Products warrants the roto-molded body to be free from defects in material 
and workmanship, under normal use and service for a lifetime. Sandia Products 
warrants the motors to be free from defects in material and workmanship, under 
normal use and service for two (2) years from the original date of sale and the 
pump/electrical parts one (1) year. Parts replaced or repaired under this warranty 
are warranted for the remainder of the original warranty period. Service labor 
charges are covered for one (1) year from the date of purchase, when performed by 
a manufacturer-authorized service provider. 
Labor is only provided by authorized service centers.  If an authorized service 
center is not near you, it is the purchaser’s responsibility to take their machine to an 
authorized service center.
Normal wear items such as capacitors, cords, finishes or switches will be warranted 
for manufacturing defects for ninety (90) days from the purchase date.
All warranties of motors and associated components will be voided: if the machine 
is serviced by anyone other than an authorized service provider; if the machine is 
mechanically modified; if the machine is operated when not operating properly; or if 
the machine is misused or abused.
The warranty starts on the purchase date by the original purchaser from Sandia 
Products subject to proof of purchase. The Machine Registration Card must be 
completed and returned immediately at the time of purchase.  Registration may 
also be performed online at: www.sandiaplastics.com/registration.aspx. If proof of 
purchase cannot be identified, the warranty start date is ninety (90) days after the 
inventory stocking date at the distributor’s warehouse.

Make a copy of this card for future reference.

Copyright © 2016 Ultimate Solutions | Sandia Products. All Rights Reserved.

Ultimate Solutions Corporate Office

15571 Container Lane, Huntington Beach, CA 92649

Phone: 800-983-5834  |  Fax: 714-901-8404

www.us-group.com  |  www.sandiaplastics.com

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 80-5000

Page 1: ...e for two 2 years from the original date of sale and the pump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...nnection of Solution Hose 13 5 4 Power Priming the High Pressure Pump 14 5 5 Connection of Vacuum Hoses 14 5 6 Connection of Auto Dump Hose 15 5 7 Adjusting the Pressure 16 5 8 Switch Panel 17 6 0 Shu...

Page 4: ...t send parts or equipment back to the manufacturer without an RMA Number and approval No labor will be paid for nor parts cost paid for or reimbursed that have not previously been approved by the manu...

Page 5: ...throughout the assembly process Prior to packaging your equipment was again inspected for assurance of flawless operation This machine is protectively packed to prevent damage in shipment We recommend...

Page 6: ...NOT leave machine outdoors in extreme heat or cold Harsh weather elements will damage components and void warranty DO NOT pick up anything that is burning or smoking such as cigarettes matches or hot...

Page 7: ...y a qualified electrician This electric equipment is for use on a normal 120 volt circuit It has a grounded plug that looks like the plug illustrated in Fig A The use of a temporary adaptor is NOT rec...

Page 8: ...rranty Chemical Metering the Hard Surface Extractor is equipped with an automatic water fill chemical feed metering system As the solution tank fills with water cleaning concentrate is drawn into the...

Page 9: ...r supply to prevent the solution tank from becoming completely full With the cleaning completed and the solution pump turned off disconnect the fill hose from the faucet drain the water in the fill ho...

Page 10: ...vacuum system can be used with one vacuum motor for cleaning delicate fabrics or both vacuum motors for carpet cleaning water extraction and hard surface cleaning Automatic Vacuum Shut Off The float...

Page 11: ...wer to operate the machine Plug the two 2 cords into two 2 outlets from different circuits 5 2 Water and Chemical Dilution Auto Fill The chemical dilution rate is controlled by the metering tip and th...

Page 12: ...y Thicker more viscous chemicals will dilute at a different rate DO NOT use powdered chemicals in the machine Use of powdered chemicals will void your warranty Contact your distributor if you have que...

Page 13: ...e to the solution outlet female QD on the front of the machine Connect the other end of the hose to the male QD on the cleaning tool When you are ready to start cleaning turn the solution pump switch...

Page 14: ...tank full 10 Float shut off filter clogged 11 Ball stuck in float shut off 12 Auto dump pump out check valve stuck open 13 Recover tank damaged 1 Replace vacuum motor 2 Replace gasket 3 Replace gasket...

Page 15: ...6 Replace pump motor 7 Repair or replace pump head and bearing check motor and or replace complete pump and motor assembly Low Solution Pressure and or Pulsation 1 Jets too large for pressure desired...

Page 16: ...n or contact your distributor for advice or assistance To increase solution pressure turn the regulator knob clockwise To decrease solution pressure turn the regulator knob counter clockwise 7 0 Maint...

Page 17: ...to the motor base Lift the tanks back onto the base and restore the latch IMPORTANT this filter must be cleaned at least once a week to prevent water blockage to the pump 7 12 Flush Chemical System Ch...

Page 18: ...ntenance procedure should be performed regardless of whether the waste pump out has been used After cleaning the recovery tank remove the cap and connect the green 3 4 x 50 foot garden hose to the aut...

Page 19: ...nk Unscrew the filter counterclockwise and rinse with fresh water If necessary use a tooth brush to remove detergent build up Note a heavy build up is a warning sign that the solution system should be...

Page 20: ...new or cleaned bag Close lid and secure latch Filter Bag Lid O Ring Latch Filter Body Vacuum Shut Off Assembly 7 0 Maintenance Continued 7 6 Clean Auto Dump Pump Out The auto dump pump out system is...