INPUT TEST
This feature allows you to test settings for each input.
Press the
F
9
SETUP MENU button.
Use the buttons
4
and
6
to move to the
INPUT TEST
item and
press
ENT
.
The corresponding value changes upon input.
0 : It indicates that the input port is open circuit.
1 : It indicates that the input port is short circuited at the earth-grounding
level.
2 : It indicates that the corresponding port is not connected.
EX : Exit Button Input
DC : Door Contact Sensor Input
I1 : Auxiliary Input #1
I2 : Auxiliary Input #2
TP : Tamper Switch Input
OUTPUT TEST
This feature allows you to test settings for each output.
Press the
F
9
SETUP MENU button.
Use the buttons
4
and
6
to move to
OUTPUT TEST
and press
ENT
Press
ENT
to turn ON/OFF the DOOR RELAY, ALARM RELAY, TTL#1,
TTL#2, BUZZER in sequence.
DOOR RELAY
(ON/OFF)
ALARM RELAY
(ON/OFF)
TTL#1
(ON/OFF)
TTL#2
(ON/OFF)
BUZZER (ON/OFF)
Press any key to move to the parent menu.
The fi rst two tests verify if the output relays (Door Relay and Alarm Relay) are
working properly. You can hear the mechanical sound of relay with a blinking
LED indicator.
The next two tests are to verify TTL#1 and TTL#2 outputs. Finally, the last test is
for an Internal Buzzer test. You can hear two beeps during the test.
1.
2.
3.
•
•
1.
2.
3.
•
4.
M
2.INPUT TEST
EX DC I1 I2 TP
2 2 2 2 0
2.INPUT TEST
EX DC I1 I2 TP
2 2 2 2 0
3.OUTPUT TEST
3.OUTPUT TEST
DOOR RELAY
ON
3.OUTPUT TEST
DOOR RELAY
OFF
PRESS ANY KEY…