62_
additional features
additional features
WIEGAND OUTPUT SETUP
Press the
F
2
SETUP MENU button.
Use the buttons
4
and
6
to move to the
WIEGAND OUTPUT
item
and press
ENT
.
Use the buttons
4
and
6
to select either
USE
or
NOT USE
and press
ENT
.
USE : It sends 26 bit Wiegand Output (34 bit for SSA-S30X1 series)
through two TTL output ports (TTL OUT #1, TTL OUT #2), which
can be used as a reader in connection with other controller.
NOT USE : This product cannot be used as a reader.
When it is set to ‘USE’, the TTL #1 and TTL #2 outputs are disabled except for WIEGAND Outputs.
VOICE VOLUME SETUP
Press the
F
3
SETUP MENU button.
Use the buttons
4
and
6
to move to
VOICE VOLUME
and press
ENT
When done, press
ENT
to save your settings.
You can adjust the volume of the voice in 5 levels from 0 (mute) to 4
(maximum)
Adjust the volume level to “0” to disable voice output.
If you enter a value higher than ‘5’, the “INVALID NUMBER” message appears
and the volume stays at the previous setting.
1.
2.
3.
•
M
1.
2.
3.
•
M
7. WIEGAND OUTPUT
NOT USE
7. WIEGAND OUTPUT
J
NOT USE
7. WIEGAND OUTPUT
J
USE
1.VOICE VOLUME
VOLUME : 0
1.VOICE VOLUME
VOLUME : _
1.VOICE VOLUME
VOLUME : _