52_
I/O time setup
I/O time setup
Output Setup for Level 4 IDs Accessing READER #2
Press the
F
6
SETUP MENU button.
Use the buttons
4
and
6
to move to the
RD2 ID OK LV4
item and
press
ENT
.
The operation time for each output is the same as in “Output Setup for
Level 1 IDs Accessing READER #2” above. (see page 51)
READER #2 ERROR OUTPUT SETUP
READER #2 ID Error Output Setup
Press the
F
6
SETUP MENU button.
Use the buttons
4
and
6
to move to the
RD2 ID ERROR
item and
press
ENT
.
You can make input when the prompt blinks.
If you enter ‘00’, no output setting is configured.
Use the keypad to enter the time for each output operation and press
ENT
.
DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output
The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time
unit.
1.
2.
•
1.
2.
3.
•
•
M
11.RD2 ID OK LV4
D R A R T 1 T 2 B Z
0 5 0 0 0 0 0 0 0 0
12.RD2 ID ERROR
D R A R T 1 T 2 B Z
0 0 0 3 0 0 0 0 0 0
12.RD2 ID ERROR
D R A R T 1 T 2 B Z
_ 0 0 3 0 0 0 0 0 0