5-35
[11] Diagnosis
Function
You can set a regular interval to diagnose the PSTN interface of the SMG-400.
Setting it to ‘0’ it bypasses the diagnosis. You can set the interval at units of 1sec
by the test type.
Procedure
1. In the <PSTN Configuration Menu> screen, type ‘11’, and press [Enter].
<<<<< Diagnosis >>>>>
+---+-----------------+---------+--------+--------+
| No | Diagnosis Items
| Period
| Unit
| Default
|
+---+-----------------+---------+--------+--------+
| 0
| SLI Port Test
| 0
| 1 sec
| 0
|
| 1
| Trunk Seizure Test
| 0
| 1 sec
| 0
|
| 2
| Trunk CODEC Test
| 0
| 1 sec
| 0
|
+---+-----------------+---------+--------+--------+
[ . :Exit ]
2. Input the number of the diagnosis interval to be changed, and press [Enter].
Configuration Item Number:
3. Set the diagnosis interval referring to the following table, and press [Enter].
Typed number x 1sec is the actual time.
No
Item
Description
0
SLI Port Test
Sets the diagnosis interval for SLI port test.
1
Trunk Seizure Test
It sets the diagnosis interval for trunk seizure
test.
2
Trunk CODEC Test
It sets the diagnosis interval for trunk CODEC
test.
SLI refers to SLC, Trunk refers to LOOP and E&M.