5-47
[2] VoIP Gatekeeper Option
Function
You can set information required for Gatekeeper connection when the SMG-400
is to be connected to Gatekeeper.
Procedure
1. In the <VoIP Configuration Menu> screen, type ‘2’, and press [Enter].
<<<<< VoIP Gatekeeper Option >>>>>
+---+---------------------+--------------+--------+
| No | Items
| Value
| Default
|
+---+---------------------+--------------+--------+
| 0
| Gatekeeper Connection
| Disable
| Disable
|
|
| Gatekeeper Status
| Unregistration
| ..
|
| 1
| RAS Method
| Auto
| Auto
|
| 2
| Registration Type
| E.164 in GW Name
| GW Name |
| 3
| Gatekeeper Type
| Other GK
| Other GK |
| 4
| GW Routing In GK mode
| Disable
| Disable
|
| 5
| Gatekeeper IP
| 0.0.0.0
| ..
|
| 6
| Gatekeeper Alias
| Gatekeeper
| ..
|
| 7
| Alternative Gatekeeper IP
| 0.0.0.0
| ..
|
| 8
| Gatekeeper Down Option
| Alternative GK
| Alternative
|
| 9
| Gateway Name | H.323 ID
| MG400 | ..
|
|10
|
| E.164
| 400 | ..
|
+---+---------------------+--------------+--------+
[ . :Exit, - :Null ]
2. Input the item number to be changed, and press [Enter].
Configuration Item Number:
3. Set values for the selected item referring to the following table, and press
[Enter]. The settings of No.6,9,10 can be ‘Null’, when if necessary. In that
case, it sends the ‘Null’ to the connected Gatekeeper.
No
Item
Description
0
Gatekeeper
Connection
Sets whether Gatekeeper is to be connected.