7. Troubles
●
Error code :
A1-5113
●
Error message :
Motor Failure: #A1-5
persists
●
Symptom / Cause :
1. Toner motor is broken.
2. The relative connectors are disconnected.
3. Deve joint board and main board are defective.
●
Troubleshooting method :
1. Print a Supply information. If the total pages of Tone
Check whether the seal is not removed.
2. Open Front-cover and check if the toner supply sys
3. Check if the Toner prevention stopper is removed.
4. Turn off then on.
5. If the problem persists, Check whether the Toner S
(
Diagnostics > Engine Diagnostics > Engine Tes
6. If the motor does not operate, check the signals and
(Voltage of red wire is 0V and black wire is 24V.)
Service Manual
7-A
shooting
:
5513. Turn off then on. Call for service if the problem
er cartridge is under 1,000, take off Toner cartridge.
tem is defective.
upply motor operates by SVC mode.
st Routines > 100-0410)