4.Servic
4.6.11. Cool Down Mode
•
Service Functions > Cool Down Mode
Purpose
- If the problem is occurred at th
mode to prevent abnormally ove
- User can set the stabilization t
- User can set the stabilization t
Operation
Procedure
Enter the cool down mode and
- Off
- 30 sec
- 50 sec
- 70sec
Verification
Print the test page and verify wh
Specification
N/A
Reference
Default time of the cool down m
If the time sets under default, pr
Service Manual
4-4
ce Mode
he side thermistor, fuser performs the cool down
erheating.
time
time
set the stabilization time.
hether the cool down mode is performed.
mode is 70 sec.
roblems can occur at the fuser.
SAMSUNG ELECTRONICS