Samsung Electronics
Service Manual
System Overview
3-6
4) USB 2.0 & IEEE1284
Elbruz machine can be connected to Host computer through IEEE1284 Parallel cable or USB cable.
IEEE1284 communication function is provided by the CHORUSm and USB function is provided by ISP1582-USB2.0
controller.
5) Engine Interface.
Engine interface is comprised of HVPS interface, SCF interface, motor interface, LSU interface, fixing unit interface and
the other photo-sensors.
All engine interface is connected directly to the Main CPU and is controlled by Firmware.
6) Scan Interface
Scan interface is comprised of CCD interface, Platen and ADF interface.
CCD is interconnected to the CPU via CCD interface and Platen motor also connects to the CPU so that move the CCD
along its way.
ADF Kit will be connected through scan interface and is recognized and enabled by the CPU.
7) Network Option Kit Interface
Network Option Kit is able to installed by end user easilly. After align its connector he or she only push option card
against Main board.
Network option card enables PostScript function at the same time as it installed properly.
Network option enables ElbruzSEC to connect to the LAN or Internet network.
Many users can share the machine and print out by internet or LAN connection.
8) Control Panel
Control Panel is prepared for communication with user.
Control panel gets the user°Øs command input and displays the machine status.
Command input will be achieved by pressing a specific key then Micom recognize which key is pressed and machine will
respond proper action.
And machine can notify its state by displaying text on the LCD panel.
- Liquid Crystal Display
- Micom : OPE Micom gathers Key pressing information ,controls the LCD and LED.
OPE Micom always communication with Main CPU periodically in order to send key input information, to receive text
which will be display on LCD and to receive the LED information which LED must be lighted.
9) Modular Board
Modular board, treated as LIU board, has only RJ-11 modular jack and some protection parts in it.
DAA has almost function of LIU board, only modular jack is needed for Line connection.