connection
ConTrol Via rs-485 inTErfaCE(sCb-5003Ph)
The camera can be controlled by using external controllers like a Remote controller. (RS-485
Communication)
(1) To control by PC
Connect the RS-485 control port of the camera and the serial cable through an RS-485
converter.
Example) PC Serial Port (COM1)
Serial Cable
RS-485 Converter
Camera RS-485Control Port.
(2) To control using a DVR or System Controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the 485 control board
that is connected to the DVR or System Controller.
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL (TRX+)
485+
(- ) CONNECTION TERMINAL (TRX-)
485-
* RS-485 Communication establishment initial value
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
M
`
To control the camera by constructing an additional controller, use the SAMSUNG-T, SAMSUNG-E,