4. Troubleshooting
► Error Code
H1-1222
► Error message
Tray 2 cassette Out / Tray 2 cassette is pulled out. Insert it properly
► Symptom
Tray 2 cassette is pulled out.
► Troubleshooting method
1) Insert the tray 2 cassette correctly.
2) If the problem persists, check the cassette detection sensor. If it is defective, replace it.
3) If the sensor is normal, replace the SCF board.
► Error Code
H1-1230
► Error message
Error: #H1-1230 / Tray Failure: #H1-1230. Check tray 2 connection & turn off then on. Call for service if the problem
persists
► Symptom
Connection between the main machine and the SCF unit is abnormal.
► Troubleshooting method
1) Check the harness connection between the main machine and the SCF unit.
Reconnect the harness.
2) If the problem persists, replace the SCF board.
3) If the SCF board is normal, replace the Main board.
Copyright© 1995-2017 SAMSUNG. All rights reserved.