OfficeServ 7400
INSTALLATION
TECHNICAL MANUAL
PART 3 MAY 2010
3.53
VM1 Status LED:
This indicates that one or more of the embedded ports (port 1 thru 4) are off
hook.
VM2 Status LED:
This indicates that one or more of the ports on the 1st installed VPM are off
hook.
VM3 Status LED:
This indicates that one or more of the ports on the 2nd VPM are off hook.
HDD Access LED:
The HDD access LED will flash whenever the Hard Drive or CF is being accessed.
LAT Status LED:
This indicates that the LAN port is active.
LRT Status LED:
This indicates that the LAN port is receiving and/or transmitting data.
SDN Status LED:
This is the System Status LED showing the operating status of the card. A status
of green indicates the SVMi-20E is down and it is safe to power off the switch. A status of red
indicated the SVMi-20E is up and running and it is NOT safe to power down the switch without
possible corruption to the SVM databases.
PGD Status LED:
Green indicates that good power is being provided to the SVMi-20E through the
Back Plane
INSTALLING THE SVMi-20E
When installing a SVMi-20E card, it is important to remember that it is a single board
computer (SBC), much the same as any desktop PC and it is therefore very important not to
exceed these environmental limits. Note: Before installing this card it should be correctly
configured with the appropriate drive, number of Voice Processing Modules (VPMs), and all
other optional add on modules (Modem and/or 64MB DRAM).
When configuring the SVMi-20E for more than 16 ports it should be installed in slots 3, 4 or 5
of the main 7400 cabinet as these are 32 channel slots. When 16 or less ports are used the
SVMi-20E can be installed in any universal slot in the system.
IMPORTANT NOTE:
If one 8 port VPM module and one 4 port VPM module are used, the 8
Port VPM must be used in connector S2 which is the third position. If reversed, no VPM ports
will come into service. (See table below).
Table 3.24 VPM Modules Configuration
Configuration Included on SBC
VPM in SL2
VPM in SL3
Total Ports
1
4 None None 4
Voice
2 4
VPM-E
None
8
Voice
3
4
VPMF-E
None
8 Voice Supporting 1 Fax
4
4 VPM-E VPM-E 12
Voice
5
4
VPM-E
VPMF-E
12 Voice Supporting 1 Fax
6
4
8VPMF-E
None
12 Voice Supporting 1 Fax
7
4
VPMF-E
VPMF-E
12 Voice Supporting 2 Fax
8
4
8VPMF-E
VPM-E
16 Voice Supporting 1 Fax
9
4
8VPMF-E
VPMF-E
16 Voice Supporting 2 Fax
10
4
8VPMF-E
8VPMF-E
20 Voice Supporting 2 Fax
Note: The Fax DSP does not increase the available ports. It adds the fax functionality to any
voice port in the SVMi-20E.