CHAPTER 2. MMC Programming
OfficServ 7200 Programming Guide
Samsung Business Communications
2-358
No
Code
Alarm Name
Definition
80 MNF17 PSU
Alarm
Rec Over-configuration of cabinet has been corrected.
Alarm Data = Cabinet, Slot (Cx-Syy)
81
MNF18
SLI Fault
An SLI card has been detected as out of service via an
internal CODEC test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
82
MNF19
SLI Recovery
An SLI card detected as out of service has been de-
tected as recovered and is in service via internal CO-
DEC test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
83
MNF20
PSUB Alarm
Indicates there are over 120 ports in a cabinet with two
PSUs.
Alarm Data = Cabinet, Slot (Cx-Syy)
84
MNF21
DSS Alarm
System capacity of 64-button DSS modules has been
exceeded.
85
MNF26
SIO RxQ Over
SIO Tx Queue full error has occurred in the MCP2.
Alarm Data = SIO number (SIO: x)
86
MNF27
SIO RxQ Under
SIO Tx Queue under error has occurred in the MCP2.
Alarm Data = SIO number (SIO: x)
87
MNF28
LAN Printer Err
LAN printer error has occurred in the MCP2.
Alarm Data = Data Type (SMDR)
88
MNF29
LAN Printer Rec LAN printer error has recovered in the MCP2.
Alarm Data = Data Type (SMDR)
MNG--
Minor Error
Minor Fault without Alarm Buffer saving
89 MNG01 Phone
Discon-
nect
Indicates the Phone is disconnected.
Alarm Data = Tel number or Cx-Syy-Pzz
90 MNG02 Phone
Connect Indicates the Phone is connected.
Alarm Data = Tel number or Cx-Syy-Pzz
91
MNG03
Off Hook Alarm
Indicates Extension Off Hook Alarm timer has expired.
Alarm Data = Tel number or Cx-Syy-Pzz
92
MNG04
On Hook
Indicates the Off Hook Alarm Extension is on hook.
Alarm Data = Tel number or Cx-Syy-Pzz
93
MNG05
MGI Packet Loss Indicates the MGI connection RTP packet loss is more
than 10 %.
Alarm Data = Tel number or Cx-Syy-Pzz
94
MNG06
MGI Packet Delay Indicates the MGI connection RTP packet delay is more
than 500 ms.
Alarm Data = Tel number or Cx-Syy-Pzz