CHAPTER 2. MMC Programming
OfficServ 7200 Programming Guide
Samsung Business Communications
2-144
Timer Name
Default
Range Unit
Description
TRK AUTOMOH DISC
60 1-250 SEC When set to ON, incoming trunk calls are
connected to MOH automatically after the
DISA ANSWR timer (MMC 503) expires. In
this case the caller hears MOH. If the TRK
AUTOMOH DISC timer expires before the call
is answered, the call is disconnected.
TSW CONN. DELAY
0 0-10 SEC
When an incoming trunk makes an outgoing
call to another trunk, the system connects the
voice path after this time.
UCDS AUDIO ALARM
0 0-990 SEC
When an SVMi-20 card is installed and the digital
UCD package enabled, this counter determines
the maximum number of seconds a call has been
waiting at the UCD group before the UCD
group’s SUPV key begins to flash along with an
audio alarm. For more UCD alarm conditions,
see MMC 500.
UCDS VISUAL ALARM
0 0-250 SEC When an SVMi-20 card is installed and the
digital UCD package enabled, this counter
determines the maximum number of seconds
a call at the UCD group before the UCD
group’s SUPV key begins to flash as an
alarm. For more UCD alarm conditions, see
MMC 500.
VOIP RE-ROUTE TM
15 0-25 SEC
If an outgoing call made via a VoIP trunk does
not receive an acknowledgement message
from the called party within this time, the call
is treated as failed.
Some timers are disabled when their value is set to ‘0’.
DEFAULT DATA
SEE DESCRIPTION
SOME TIMERS DEPEND ON COUNTRY