[501] SYSTEM TIMERS
Allows the technician to adjust individual timers as necessary.
TIMER TABLE
Timer Name
Default
Range Unit
Description
ALARM TIME
100 0-2500 MIN This is the time the system alarm key will start
ringing after the alarm key has been silenced.
ALERT TONE TIME
1000 100-2500
MSEC
This timer sets the duration of the attention
tone preceding a call to a phone in the Voice
Announce or Auto Answer mode. This tone
will also precede a forced Auto Answer call.
ALM REM.INTERVAL
25 1-250 SEC This timer controls the time between ring at-
tempts at a station when alarm reminder is
set.
ALM REM RING OFF
10 1-25 SEC
This timer controls the length of the ring cycle
duration when an alarm reminder is set at a
station.
ATT. RECALL TIME
30 0-250 SEC This controls how long a transfer recall will
ring at a station before recalling the operator.
AUTO REDIAL INT.
30 1-250 SEC This timer controls the time between attempts
after RETRY dialling is set on a station.
AUTO REDIAL RLS.
45 1-250 SEC This timer controls the duration of a Ring No
Answer condition on a retry number dialled
before the auto redial is automatically can-
celled.
BOOTH TIME OUT
(Hotel application only)
005 0-250 MIN
Controls the time for which a booth phone is
enabled.
CALLBACK NO ANS
30
1-250 SEC This timer controls the time before the call-
back is automatically cancelled when a call-
back detects Ring No Answer.
CAMP ON RECALL
30
0-250 SEC This timer controls the time a camped-on call
will stay at a destination before recalling to the
transferring station.
CID MSG RECEIVE
6
1-25 SEC
The amount of time that the system will allow
a valid message from the analogue CID trunk.
CID DSP ALLOC TM
500
000-500
MSEC
Caller ID (CLI) Digital Signal Processor Alloca-
tion timer - the length of time the DSP is in-
circuit to decode analogue Caller ID.
CLI DISPLAY TIME
5
1-25 SEC
The amount of time that the Caller ID informa-
tion remains on the phone’s display.
CO CLEAR TIME
30
0-250 SEC The length of time a Direct Trunk Select key
remains busy after cleardown.