2-14
Samsung Electronics
Product Specifications
Wired Remote Control Installation
(cont.)
3. Using more than two screws, firmly affix the rear cover of the remote controller to the wall, and then connect
the power(V1, V2) and communication cables(F3, F4), making sure these cables have reasonable length,
to the terminal at the back of the cover.
4. Reassemble your Wired Remote Controller.
●
When installing a Wired Remote Controller by using a cable longer than 10m, you must install the communication cable and the power
cable separatery. (Electrical interference can cause your Wired Remote Controller to malfunction.)
●
When installing your Wired Remote Controller on the wall, consider the size of the wire hole, and select a wire with a proper thickness.
●
Wire that is connectable to Wired Remote Controller PCB.
- If you install the Wired Remote Controller by reclaiming, install it according to U-terminal cable specification.
- If you install the Wired Remote Controller by using four pieces of PVC wire, remove the 30cm of the sheath of the cable and install
it only with the four pieces of wires. (Recommended specification: AWG21)
●
The following are the specs of the compression ring terminal connected to your Wired Remote Controller PCB.
●
Screws on the PCB terminal must be tightened with less than 6N-cm tightening torque. If the tightening torque is greater, it may damage
the screw thread.
●
Align the controller with the upper groove first, and insert it by turning it downward as shown
in the figure.
After assembly, check and confirm that no wires are stuck in the gap between the rear and
front cover.
10mm or more
10mm or more
50mm or more
10mm or more
Screw hole
Rear cover
Front cover
PCB terminal
Wire (not supplied)
Before fixing the rear cover, secure at least
10mm space of upper side, left side,
right side, and 50mm space of bottom side.
You must fit the screws into
the screw holes.
Indoor unit
Wired Remote
Controller
Do not tighten the screws on the
PCB terminal with excessive force.
W
t
G
E
F
L
Stud
D
Range of Permitted Wires
Rated
Size
Stud
Size
Basic Size (mm)
AWG
mm
2
mm
2
mm
t
øD
G
E
F
W
L
22~16
0.25~1.65
1.5
3
0.7
3.8
10.0 4.5
6.5
6.0 21.2
Maximum distance for connecting communication and power cable: 100m