4. Troubleshooting
► Error Code
U1–2335
U1–233A
► Error message
Fuser Unit Failure: #U1-2335.
Fuser Unit Failure: #U1-233A.
► Symptom
Temperature of the thermistor is abnormally low.
► Troubleshooting method
•
U1–2335 : Error occurs at non-contact type Thermistor
•
U1–233A : Error occurs at contact type Thermistor
1) Turn the machine off. Re-install the fuser uni, then turn the machine on.
(Refer to 3.3.2. Fuser unit)
2) Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
3) Remove the fuser unit. After opening the jam cover, check if jammed or wrapped paper is in the fuser unit.
4) If the problem persists, Check the follows.
(Refer to 3.3.23. Fuser unit)
a) Check if the Halogen lamp
(110V : 4713–001632 / 220V : 4713–001633)
is broken or disconnected.
b) Check if the AC connection of the Halogen lamp is disconnected or contaminated.
c) Check if the thermistat
(4712-001098)
is disconnected.
d) Check if the contact type thermistor
(1404–001567)
or Non-contact type thermistor
(1404–001453)
is broken.