4. Troubleshooting
► Error Code
A3–3111
A3–3112
A3–3113
A3–3114
► Error message
Sensor Failure: #A3-3111. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3112. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3113. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3114. Turn off then on. Call for service if the problem persists
► Symptom
The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to a defective harness.
► Troubleshooting method
•
A3–3111 : Center NC sensor is in short status.
•
A3–3112 : Center NC sensor is in open status.
•
A3–3113 : Side NC sensor is in short status.
•
A3–3114 : Side NC sensor is in open status.
1) Remove and disassemble the fuser unit.
(
Refer to 3.3.23 Fuser Unit
)
2) Measure the resistance value of the thermistor (
1404-001453
). If the measured value is out of 307KΩ~430KΩ
@25
℃
, replace the thermistor.
3) Install the fuser unit after replacing the thermistor.
4) If the error persists, replace the fuser unit (
JC91-01163A(220V) / JC91–01164A (110V)
).
5) If the error persists after replacing fuser unit, replace the main board(
JC92–02746A
).
4-77
Copyright© 1995-2017 SAMSUNG. All rights reserved.
Summary of Contents for MultiXpress K4 Series
Page 10: ...Contents 6 4 Document Revision List 6 10 ix Copyright 1995 2017 SAMSUNG All rights reserved ...
Page 53: ...2 Product Specifications and Description Copyright 1995 2017 SAMSUNG All rights reserved 2 37 ...
Page 76: ...2 Product Specifications and Description 2 60 Copyright 1995 2017 SAMSUNG All rights reserved ...