Feature & Operation
Samsung Electronics
74
6-1-3 Automatic Operation
When Automatic operation is set by the remote control, the air conditioner senses the room temperature then automatically selects the
operation mode and setting temperature.
1. In case of Heat pump model.
1.
◆
In case that Room Temp.
≥
21°C +
∆
T, the unit is operated in the Cool Mode.
1.
◆
In case that Room Temp. < 21°C +
∆
T, the unit is operated in the Heat Mode.
1.
◆
∆
T means that user is able to change setting temperature within ±2°C.
2. In case of Cooling only model.
1.
◆
In case the Room Temp.
≥
25°C +
∆
T, the unit is operated Compressor.
1.
◆
In case the Room Temp.
≤
24°C +
∆
T, the unit is not operated Compressor.
1.
◆
∆
T means that user is able to change setting temperature within ±2°C.
Operating Mode
Setting Temp.
Remarks
Room Temp
≥
21°C +
∆
T
Cooling
Tsp = 24°C +
∆
T
∆
T = -2, -1, 0, 1, 2°C
Room Temp < 21°C +
∆
T
Heating
Tsp = 22°C +
∆
T
Operating Type
Room Temp.
Remarks
Cool Operation
Tr
≥
25°C +
∆
T
Compressor ON
∆
T = -2, -1, 0, 1, 2°C
Tr
≤
24°C +
∆
T
Compressor OFF
DB98_20402A(1)_1 10/26/04 2:58 PM Page 74