Operation Instruction & Installation
41
Samsung Electronics
3-7-6 Refrigerant Adjustment
It would be the best choice to use the standard tube length to keep the basic quality of Room Air conditioner, for example cooling and
heating capacity, sound level, vibration level, and reliability.
But, according to a certain different installation condition, the connection tube length could be changed in the recommendation length
that is shown above.
In this case, installer should keep the installation condition to keep the quality of Room Air conditioner.
●
Refrigerant should be charged additionally as written above according to the change of the length of the connection tube.
It needs to affect the decrease in cooling and heating capacity or of the reliability of compressor that may be caused by a lack of refrigerant.
●
Installation position difference between the indoor unit and the outdoor unit should not exceed over than “B” meters.
●
When the connection pipe is been extended longer than 5 meters, it might need to change the diameter of the electrical wire to a larger size
in order to keep a voltage drop for starting room air conditioner is not less than 85% of the rated voltage. And then, a voltage meter will be
useful to check the rate of the voltage drop.
3-7-7 Flare Nut Fixing Torque
Class
At installation
At service
Connection
Pipe Length
Standard
< TOTAL
≤
40m
Max.
< TOTAL = 70m
Air-Purge
Method
Refer to the
detailed Air-Purge
Procedure
Refrigerant
Adjustment
Unnecessary
Add "15g" of refrigerant
(R410A) for every 1m.
Air-Purge
Method
Purge air using a
vacuum pump
or an additional
refrigerant cylinder.
Refrigerant
Quantity
refer to
specification sheet
Add "15g" of refrigerant
(R410A) for every 1m.
ø 6.35 mm
(Liquid Side)
ø 9.52 mm
(Gas Side)
ø 12.7 mm
(Gas Side)
160
300
500
200
350
550
Outer diameter
Torque (kg-cm)
Fixing Torque
Final Torque
DB98_20402A(1)_1 10/26/04 2:48 PM Page 41
Summary of Contents for MH052FDEA
Page 106: ...MEMO 105 Samsung Electronics ...
Page 113: ...Samsung Electronics 112 Exploded Views and Parts List 1 2 8 9 10 11 3 6 7 4 5 ...
Page 132: ...131 Samsung Electronics 11 PCB Diagram 11 1 MAIN PCB Indoor Unit TOP ...
Page 133: ...Samsung Electronics 132 PCB Diagram BOTTOM ...
Page 136: ...135 Samsung Electronics 11 2 MAIN PCB Outdoor Unit 11 2 1 MH068FXEA4 MH080FXEA4 TOP ...