Operation Instruction & Installation
43
Samsung Electronics
3-7-9 Performing Leak Tests
Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation
plate), you must check that there are no gas leaks.
To check for gas leaks on the...
Then, using a leak detector,
check the...
Indoor unit
Flare nuts at the end of sections
C and D.
Outdoor unit
Valves on sections A and B.
A B
C
D
DB98_20402A(1)_1 10/26/04 2:48 PM Page 43