Operation Instruction & Installation
Samsung Electronics
46
3-7-12 Switch Setting and Testing operation
To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly.
Step 1 :
Review all the following elements in the installation:
Step 1 :
• Installation site strength
Step 1 :
• Piping connection tightness to detect any gas leakage
Step 1 :
• Connection wiring
Step 1 :
• Heat-resistant insulation of the piping
Step 1 :
• Drainage
Step 1 :
• Earthing wire connection
Step 2 :
Check the room select switch in the indoor unit and in the outdoor unit.
Step 1 :
Set the switch properly as below. (For example: 4Rooms)
Step 1 :
• The liquid and gas refrigerant pipes should not be crossed with each other.
Step 1 :
• The switch for the indoor unit address setting is in each indoor unit PCB.
Step 3 :
Automated checking of pipe connection (Auto addressing option)
Step 1 :
• Apply the power to the outdoor unit.
Step 1 :
• Push the [K2] button 4 times in the outdoor PCB display.
Step 1 :
• It could take more time depending on the indoor and outdoor temperature.
Step 1 :
• If the checking is finished, outdoor unit stops automatically.
Step 1 :
• [DIS 02] shows the indoor unit under searching.
Step 1 :
• Function of
Step 3
OUTDOOR UNIT
A unit
B unit
C unit
D unit
K 1
K 2
K 3
(OFF)
DIS01
SW02
SW01
K 4
DIS02
Outdoor PCB Display
A unit
Indoor unit
Manual Addressing
(For example: 4 Rooms)
Auto Addressing
(For example: 4 Rooms)
B unit
C unit
D unit
SW02
SW02
SW02
SW02
SW02
SW02
SW02
SW02
SW 01
Outdoor unit
Manual Addressing
(For example: 4 Rooms)
Auto Addressing
(For example: 4 Rooms)
SW 02
Button [K2]; 4 times
Display
Time duration
DIS 01
15°C or more
(Cool mode)
5 min ~ 10 min
(Heat mode)
20 min ~ 50 min
Less than 15°C
Outdoor Temperature
[DIS01] is flickering on the setting time.
DIS 02
Function
Mode
Auto Addressing
Manual Addressing
Checking the connection & addressing
Checking the connection only
DB98_20402A(1)_1 10/26/04 2:48 PM Page 46
Summary of Contents for MH052FDEA
Page 106: ...MEMO 105 Samsung Electronics ...
Page 113: ...Samsung Electronics 112 Exploded Views and Parts List 1 2 8 9 10 11 3 6 7 4 5 ...
Page 132: ...131 Samsung Electronics 11 PCB Diagram 11 1 MAIN PCB Indoor Unit TOP ...
Page 133: ...Samsung Electronics 132 PCB Diagram BOTTOM ...
Page 136: ...135 Samsung Electronics 11 2 MAIN PCB Outdoor Unit 11 2 1 MH068FXEA4 MH080FXEA4 TOP ...