3-12
3. Disassembly and Reassembly
Part
Photo
Description
Assy Case Brake
&
Assy Case Sensor
v
mG
p
The Assy case brake & case sensor is mounted on the
left side of the tub. Its purpose is to provide a method
of supplying water for the wash and rinse cycles. The
air inlet allows air into the tub to permit air
fl
ow for dish
drying. Also the air can
fl
ow out through the air brake
when pressure inside tub.
Flow meter embedded in the Assy case brake can give
electronic pulse output to electronic controller, so the
supplying water quantity could be controlled accurately.
h GG
h GG
Preparation:
*
Make sure to disconnect the power & water supply
& drain hose connections.
*
Remove the upper & lower baskets in the
dishwasher.
*
Pull out the dishwasher carefully.
1.
Remove the two (2) screws of the frame left.
2.
Remove the frame left.
Caution
Make sure to wear gloves when removing it. Be
careful as the steel plate may harm you.
3.
Remove cover brake rotating it. (counterclockwise)
Use a jig. If you have no jig, you can use a long
nose pliers covering with fabric. (It can make scratch
or breakage, be careful)
4.
Disconnect the three(3) sensor connectors.
-
fl
ow meter, water level , over
fl
ow .
5.
Remove the Assy case sensor from the Assy case
brake.
6.
Loosen the four (4) clamps and release the four
(4) hoses from the Assy case brake and Assy case
sensor.
Caution
Remain water can come out, Must use the towel to
block the wet on
fl
oor.
坍
Reassembly is in the reverse order of the removal.