3-8
3. Disassembly and Reassembly
Part
Photo
Description
Condensing dry
system
Assy Case Vent
&
Assy Dry Duct
&
Assy Duct
Condenser
5. Remove the Assy case vent by rotating it
counterclockwise.
6. Remove the Assy dry duct from the Assy duct
condenser.
These parts are
fi
xing by four(4) hooks. To
disassemble, hooks are broke down in the Assy dry
duct.
Caution
Only when dry motor is not working, disassemble it.
After remove it, you should use new Assy dry duct
part to reassemble.
7. Pull out Assy dry duct.
Assy Case Vent
1. Remove the Assy case vent.
2. Release two screws.
3. Pull the thermal actuator
fi
rmly to remove it from the
housing and to release it from the gasket vent.
坍
Reassembly is in the reverse order of the removal.