4. Troubleshooting
4-14
Error type
Error mode
Checking Method
Corrective actions
The nozzle does not
inject water
None
1. Check the connections for the Circulation Motor
connector.
- Reconnect the Circulation Motor connector.
2. Check the connections for the Startup Condenser
connector of the Circulation Motor.
- Reconnect the Startup Condenser connector of the Circulation Motor.
3. Check the resistance for the Circulation Motor coil.
(Remove the connector before measuring.)
- Between black wire and white wire
Normal: Approx. 15
Ω
¯
- Between black wire and blue wire
Normal: Approx. 21
Ω
¯
- Faulty: Replace the Circulation Motor.
4. Check the operation of the Circulation Motor Relay.
- At No.2 mode in service inspection mode,
Check the operating voltage between the
yellow wire of the CN101 connector and the
white wire of the CN201 connector.
Normal: 120V (while operating)
¯
- At No.3 mode in service inspection mode,
Check the operating voltage between the
yellow wire of the CN101 connector and the
blue wire of the CN201 connector.
Normal: 120V (while operating)
¯
- Faulty: Replace the Main PBA assy.
- Normal: Replace the Circulation Motor.
- Remove
retainer.
- Check voltage while operating Wash motor-2(High)
- Check voltage while operating Wash motor-1(Low)
5. Check whether there is foreign material in the water
passages.
- Remove foreign material from the water passages.