Samsung Electronics
Troubleshooting
12-13
12-3-8 Compressor start error
1 Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?
2 Troubleshooting procedure
Restart after power off
Is the restart error occurred again?
Is the interphase resistance value of com-
pressor (
U
V,V
W,W
U) normal?
Is the connection cable for thecompressor
and power terminal normal?
Exchange the PCB.
Terminate the service.
Exchange the compressor.
Is the compressor body and interphase resis-
tance insulated?
Exchange the compressor.
Correct the cable connection.
Yes
Yes
Yes
Yes
No
No
No
No