![Samson Media 7 Mounting And Operating Instructions Download Page 58](http://html.mh-extra.com/html/samson/media-7/media-7_mounting-and-operating-instructions_805914058.webp)
58
EB 9510 EN
Operation of Media 7 Differential Pressure Meter
8
Operation of Media 7 Differential Pressure Meter
Once the mounting and start-up activities have been completed, you can start with the set-
tings. The differential pressure meter is ready for use immediately after the electrical power
supply has been connected.
8.1 First start-up
After the differential pressure meter is put into operation for the first time after shipment, the
wizard starts automatically after the electrical power is connected.
We recommend proceeding as follows during first start-up:
1. Run the start-up wizard (see section 8.1.1).
2. Set user level (see section 8.1.3).
3.
Perform zero calibration
(see section 8.1.4).
8.1.1 Running the start-up wizard
− The language is set to English by default on first start-up.
−
If no settings are entered within five minutes, the display returns to the start screen.
Step 1 of 6: select language
1. Select the required language with or key.
2.
Confirm the selected language with
key. Press key again to continue.
Step 2 of 6: select unit
1. Select the required unit with or key.
2.
Confirm the selected unit with
key. Press key again to continue.
Step 3 of 6: set the minimum differential pressure Δp
0
1. Select the required digit within the number with or key. Press
key to confirm
the selected digit.
Tip
Note
Summary of Contents for Media 7
Page 88: ...88 EB 9510 EN Annex ...
Page 89: ...EB 9510 EN 89 ...
Page 90: ...90 EB 9510 EN ...
Page 91: ...EB 9510 EN 91 ...
Page 92: ...92 EB 9510 EN ...
Page 93: ...EB 9510 EN 93 ...
Page 94: ......
Page 95: ......