User interface
[Operating filling limit, hazard warning]
−
Operating filling limit
Operating filling limit
in %
A blinking bar graph element on the display indicates when the operating filling limit has
been reached.
A marking can be fixed in the range between 0 % and 95 %. This is used to calculate the
tank content.
The blinking bar graph element serves as guide for the operator filling the tank.
[Calculated values]
Reading of the previously entered value and the automatically calculated value. It cannot be
edited and is only shown on the software.
−
Max. tank content [MCN] · Entered in m³
−
Tank content up to overflow/gauge pipe [SCN] · Entered in m³
−
Tank content up to 'Operating filling limit' [UCW] · Entered in m³
−
Minimum differential pressure [Δp0] · Differential pressure in mbar at 0 % filling level
−
Maximum differential pressure [Δp100] · Differential pressure in mbar at 100 % filling
level
Filling level table · Displays a table with filling levels corresponding to the tank data and
selected dimension.