CHANGES IN MEASURING UNITS
SETTING THE UNITS
Access the “UNITS” submenu according to the section
“CALIBRATION PROCEDURE” (page 6). In order to entry
in the “UNITS” submenu, press ON/RESET button (Fig.
31) once the screen is blinking (Fig. 32).
The meter can be configured to use grams [g], kilograms
[Kg], ounces [Oz] and pounds [Lb].
When making a change from one unit to another, the
conversion of the quantity stored is made both in the partial
meter and in the total meter.
After this, the display will show the selected measurement
units (Fig. 33). Press SELECT button (Fig. 34) successively
until visualizing the required measurement unit (Fig. 35).
To select the unit and save configuration, press ON/
RESET button (Fig. 36). After that, the meter will exit to the
dispensing mode automatically (Fig. 37).
Fig. 33
Fig. 35
Fig. 37
Fig. 31
Fig. 32
Fig. 36
Fig. 34
Kg
g
Oz
lb
Oz
lb
TROUBLE-SHOOTING
SYMPTOM
POSSIBLE CAUSE
SOLUTION
The meter
is inaccurate.
A fluid with very high or very low viscosity
is being used.
Calibrate the meter.
Very high or low fluid temperature.
The meter is working outside its field of
application (see technical specifications).
Adjust the operating conditions to the meter
working range.
Reduced flow.
Dirt in the measuring chamber.
Clean the measuring chamber.
The meter does not count. Faulty read sensor.
Contact with SAMSON Technical Service.